Specification
INPUT RATING (Btu/hr) 0-2000 ft (0-610 m)
INPUT RATING (Btu/hr) 2000-4500 ft (610-1370 m)
MAXIMUM OUTPUT (Btu/hr) 0-2000 ft (0-610 m)
MINIMUM INPUT (btu/hr) 0-2000 ft (0-610 m)
ORIFICE SIZE (DMS) 0-2000 ft (0-610 m (front/rear))
ORIFICE SIZE (DMS) 2000-4500 ft (610-1370 m (front/rear))
MANIFOLD PRESSURE - (in. W.c./kpa)
MANIFOLD PRESSURE - Low setting (in. W.c./kpa)
INLET PRESSURE - MINIMUM (in.w.c./kpa)
INLET PRESSURE – MAXIMUM (in. w.c./kpa)

Specifications

Figure 8 - Model 8762 Dimensions (
12
Certified for use by:
Board of State Examiners of Plumbers & Gasfitters
100 Cambridge Street, Room 1511
Boston, MA 02202
www.mass.gov
)
Inches
NG
36,000
35,000
28,200
16,000
43/46
43/47
3.5/0.87
1.1/.027
5.0/1.25
7.0/1.74
Bristol DX Model 8762
LP
33,000
30,000
26,200
10,000
54/57
55/59
10.0/2.48
6.4/1.59
12.0/2.99
13/3.22