Installing A Cf Card To An Mpu (Optional) - HP 7500 Series Installation Manual

Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

For more information about the A-RPS 800, see HP A-RPS 800 Redundant Power System User Guide.
Connecting a user-supplied power cord to the PoE input on the chassis rear panel
CAUTION:
To avoid damage to the switch, be sure to connect the negative terminals to negative terminals and
positive terminals to positive terminals.
To connect a user-supplied power cord to the PoE input on the chassis rear panel:
1.
Remove the blank panel covering the PoE port of the switch.
2.
Connect the negative OT terminal on the PoE power cord to the NEG(–) terminal on the PoE power
supply socket, and fasten the captive screw. Connect the positive OT terminal on the PoE power
cord to the RTN(+) terminal on the PoE power supply socket, and fasten the captive screw.
3.
Install the blank panel to the PoE port.
4.
Connect the PoE power cord to the external PoE power supply.
Figure 32 Connecting a user-supplied power cord
(1) NEG(-) terminal
(3) Grounding point

Installing a CF card to an MPU (optional)

If you select an MPU supporting CF card, you can install a CF card as needed.
To install a CF card:
1.
Push the CF card eject button all the way into the slot, and make sure the button does not project
from the panel.
2.
Push the CF card all the way into the CF card slot, so that it does not automatically project, as
shown in callout 4 of
3.
When the switch is powered on, examine the running status of the CF card.
Figure
33. At the same time, the eject button projects.
37