JUNCTION BOX AND 1/2" RUN HOSES (OPTIONAL)
Junction Box Kit (optional) includes:
• One (1) junction box with feet
• Four (4) 1-1/2" NPT male/slip female PVC fittings
• Two (2) –6 male JIC/-8 male JIC union
If installing the optional junction box with the 1" poly pipe:
• The Fastlane ships with two (2) 24' 6" rolls of 1" poly pipe. Do NOT cut down the length of this 1" poly
• Install the two (2) 1-1/2" liquid-tite fittings in the same side of the junction box.
• Feed the 1" poly pipe into the liquid-tite fittings and tighten the fittings so that no water will pass between
• To get from the junction box to the Power Unit, run 1-1/2" PVC flex pipe.
• Roll two (2) lengths of PVC flex pipe from the junction box to the Power Unit. The PVC flex pipe should
• Measure the length of PVC flex pipe. Your 1/2" run hose will need to be AT LEAST 4 feet longer than the
• Glue the 1-1/2" NPT male/slip female fittings on the end of the PVC flex pipe that will connect to the
• If desired, the junction box can be anchored by attaching the feet included with the kit.
If installing the optional junction box with the 1-1/2" PVC flex pipe:
• The 1-1/2" PVC flex pipe will need to be cut to 24' 6" from the wall mount bracket to the junction box.
• Glue the 1-1/2" NPT male/slip female fittings on the end of the PVC flex pipe that will connect to the
• To get from the junction box to the Power Unit, run 1-1/2" PVC flex pipe.
• Unroll the two (2) lengths of PVC flex pipe from the junction box to the Power Unit. The PVC flex pipe
• Measure the length of PVC flex pipe. Your 1/2" run hoses will need to be AT LEAST 4 feet longer then
• Glue the 1-1/2" NPT male/slip female fittings on the end of the PVC flex pipe that will connect to the
• If desired, the junction box can be anchored by attaching the feet included with the kit.
Section 6

INSTALLATION AND TESTING OF THE HYDRAULIC POWER UNIT

6.1
6.2
6.2
Fill Cap
Antenna
Low
Pressure
6.3
6.4
Proportional
High Pressure
Relief Valve
6.5
9
pipe.
the 1" poly pipe and the fittings.
exit near the Power Unit.
length of the PVC flex pipe. Order your 1/2" run hoses at this time by calling our Customer Service
Department at 800-910-2714.
junction box. Secure the fittings to the junction box with the provided lock nuts. The PVC flex pipe can be
buried in a trench.
junction box. Secure the fittings to the junction box with the provided lock nuts.
should exit the ground next to the Power Unit.
the length of the PVC flex pipe. Order your 1/2" run hoses at this time by calling our Customer Service
Department at 800-910-2714.
junction box. Secure the fittings to the junction box with the provided lock nuts. The PVC flex pipe can
be buried in a trench.
PLACEMENT CONSIDERATIONS: The Power Unit should be placed on a flat, level surface, prefer-
ably not on wet ground. If placing outside, it is recommended the Outdoor Power Unit with Weather
Guard be purchased, but should not be subject to driving rain. If placing indoors and at a level below
the pool deck, such as a basement, a floor drain is mandatory to accommodate the unlikely event of a
hole developing in the hydraulic hose creating a siphon. Whether placed indoors or out, this is an air-
cooled unit and must have ample ventilation. Therefore, a minimum of 12" air space must be provided
on all sides of the Power Unit motor. In addition, while frequent access is not required, it is imperative
the Power Unit be accessible.
Carefully remove the Power Unit from the packaging. Note: The Power Unit is very heavy. To remove
the Power Unit open box top flaps, lay box on its side, open box bottom flaps, and slide the Power Unit
out of the box sideways on the bottom foam.
Place the Power Unit in the selected position and verify that the hose connections are pointed in the
direction you desire.
Have an electrician make the electrical connections using the whip provided. Make this connection by
hard wiring to a disconnect or using an appropriate lock tight plug and socket. The Power Unit requires
single-phase 220-volt, 30-amp GFCI-protected power. Verify proper incoming voltage and wiring. Refer
to Section 7, "Power Unit Electrical Wiring." For UK and international electrical requirements, please
refer to Section 8.
• Two (2) 1-1/2" liquid-tite fittings
• Six (6) 1-1/2" locknuts
• Roll of anti-corrosion tape

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FastLane and is the answer not in the manual?

Questions and answers

Chuck McGowan
April 14, 2025

How long can the Fastlane run? Single work out or playtime for the kids

1 comments:
Mr. Anderson
April 15, 2025

The Endless Pools Fastlane can run for up to 30 minutes after receiving its last command, as the Power Unit remote control has an automatic timer that shuts off the system after that time.

This answer is automatically generated

Table of Contents