Congratulations; Sample Of Safety/Serial Number Label - Quadra-Fire 57ST-ACC Owner's Manual

5700 step top wood stove series
Hide thumbs Also See for 57ST-ACC:
Table of Contents

Advertisement

5700 Step Top Wood Stove Series ACC
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including 'Voice of the Customer' contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world's most
advanced technology to achieve the optimum operation
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
CAUTION
ATTENTION:
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. (UM)
84-HUD . "For Use with Solid Wood Fuel Only"
PREVENT HOUSE FIRES
Install
and
use
only
in
accordance
with
manufacturer's
installation
and
operating
instructions. Contact local building or fire officials
about restrictions and installation inspections in
your area. Do not obstruct the space beneath
heater.
WARNING - For Mobile Homes: Do not install in
a sleeping room. An outside combustion air inlet
must be provided and unrestricted while unit is in
use. The structural integrity of the mobile home
floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame
of the mobile home.
Components required for
mobile home installation:
Outside Air Kit, Part
Number 831-1780.
Refer to manufacturer's instructions and local
codes for precautions required for passing
chimney through a combustible wall or ceiling and
maximum offsets.
Inspect and clean chimney frequently - Under
Certain Conditions of Use, Creosote Buildup May
Occur Rapidly.
Do not connect this unit to a chimney serving
another appliance.
Optional Components:
Optional Blower, Part
831-1701.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route
cord over or in front of appliance.
DANGER: Risk of electrical shock. Disconnect
power supply before servicing.
Replace glass only with 5mm ceramic available
from your dealer.
Do not use grate or elevate fire. Build wood fire
directly on hearth.
Do not overfire - if heater or chimney connector
glows, you are overfiring.
Manufactured by:
Fabriqué par:
1445 N. Highway, Colville, WA 99114
www.quadrafire.com
Page 2
and Welcome to the Quadra-Fire Family
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: Back of Appliance
Test Lab and
Report Number
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
:
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT
PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR
L'ÉTIQUETTE ET LES INSTRUCTIONS.
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
Tested and
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
Listed by
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec
C
Bois Solide Seulement"
OMNI-Test Laboratories, Inc.
PRÉVENTION DES FEUX DE MAISON
Report / Rapport
#061-S-73-6.2
Installez et utilisez en accord avec les instructions
d'installation et d'opération du fabricant. Contactez le
bureau de la construction ou le bureau des incendies au
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black
sujet des restrictions et des inspections d'installation dans
votre voisinage. Ne pas obstruez l'espace en dessous de
or blued steel connector pipe, with a listed factory-built UL103HT* Class "A"
l'appareil.
chimney, suitable for use with solid fuels, or a masonry chimney, and the
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
referenced clearances.
une chambre à coucher. Un tuyau extérieur de
combustion d'air doit être installé et ne doit pas être
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
obstrué lorsque l'appareil est en usage. La structure
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney,
intégrale du plancher, du plafond et des murs de la
or a masonry chimney and the referenced clearances
maison mobile doit être maintenue intacte. L'appareil de
chauffage doit être fixé à la charpente de la maison
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos
mobile. Les composants requis pour l'installation des
DS or Security DL double wall connector pipe. Must be equipped with a spark
maisons mobiles: Assemblage d'air extérieur, Numéro de
Pièce 831-1780.
arrestor. Apply double wall clearances below when installing unit.
Référez vous aux instructions du fabricant et des codes
locaux pour les précautions requises pour passer une
MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
cheminée à travers un mur ou un plafond combustibles,
et les compensations maximums.
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of flue collar.
Inspectez et nettoyez la cheminée fréquemment. Sous
certaines conditions, il se peut que la créosote
s'accumule rapidement.
INSTALLATION: FULL VERTICAL INSTALLATION: ENTIÈREMENT VERTICALE
Ne pas connecter cet appareil à une cheminée servant un
autre appareil.
Composants Optionnels: Ventilateur Optionnel, Pièce
#831-1701.
SINGLE WALL PIPE
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer
DOUBLE WALL PIPE
le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.
Déconnectez le fil électrique de la prise de contact avant
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
le service.
Remplacez la vitre seulement avec une vitre céramique
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
de 5 mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement
sur l'âtre.
SINGLE WALL PIPE
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau
2009 2010 2011 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Manufacturer Date
of our stoves, inserts and fireplaces. And yet we are old-
fashioned when it comes to craftsmanship. Each unit is
meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
R
Portland
O-T L
Oregon USA
US
TESTED TO:/ TESTÉ À:
UL 1482, ULC S627-00
VENT SPECIFICATIONS:
A
B
C
D
12.5 (318) 10.5 (267) 25.5 (648)
15 (381)
2 (51)
9.5 (241) 7.5 (191) 25.5 (648)
15 (381)
2 (51)
9.5 (241) 7.5 (191) 25.5 (648)
15 (381)
Made in U.S.A./Fait Aux États-Unis
7038-159C
!
Serial Number
Model Name
007007
5700 Step Top ACC
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine
UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, ou une
cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air
isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou
une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE:
Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES:
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur
de l'entrée du conduit.
E
F
G
H
CONDUIT DU MUR SIMPLE
12 (305)
45 (1143)
N/A
CONDUIT DU MUR DOUBLE
12 (305)
45 (1143)
N/A
CONDUIT DU MUR SIMPLE
**
**
**
45 (1143) 18 (457)
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to
comply with July 1990 particulate emission standards.
R
SERIAL NO. / NUMÉRO DE SÉRIE
En Pouces & (millimètres)
BACKWALL/SIDE
A
B
WALL
C
MUR
ARRIÈRE/MUR
D
DE CÔTÉ
CORNER
E
F
INSTALLATION
INSTALLATION
DU COIN
E
F
7038-162
February 5, 2010

Advertisement

Table of Contents
loading

Table of Contents