Ring Coupling (When "Turbo Ring with ED6008 series" is enabled)
EDS supports two kinds of coupling topologies (Firmware Ver. 2.3 or later). One
is to enable "Turbo Ring with ED6008 series" and the other is to enable "Turbo
Ring with EDS series". When you enable "Turbo Ring with ED6008 series", you
could only connect ED6008s within one Turbo Ring and use this kind of ring
coupling topology shown as above.
STEP 1
Select one EDS from the left and right Turbo Ring. Enter the Communication
Redundancy pages of both EDSs and select "Turbo Ring with ED6008 series"
from "Protocol of Redundancy".
STEP 2
Select the circled EDSs and check "Enable Redundant Ring Coupling."