Table 2. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
25C0xx yy
DIMM failure (continued):
(continued)
where xx and yy are:
yy
01
02
04
10
12
14
20
21
22
24
40
41
42
44
88
25C10001
One or more DIMMs have failed.
25C10002
One or more DIMMs are not
supported.
Description
DIMM2 missing
DIMM1 unsupported and
DIMM2 missing
DIMM1 failed and DIMM2
missing
DIMM1 missing
DIMM1 unsupported
DIMM1 failed
DIMM1 missing and DIMM2
unsupported
DIMM2 unsupported
DIMM1 and DIMM2
unsupported
DIMM1 failed and DIMM2
unsupported
DIMM1 missing and DIMM2
failed
DIMM2 failed
DIMM2 failed and DIMM1
unsupported
DIMM1 and DIMM2 failed
DIMM1 and DIMM2
mismatch
Suggested action
Note: For additional information about DIMMs, see
"Installing memory modules" on page 37.
1. Make sure that all the DIMMs in the blade server are
supported. Replace all the unsupported DIMMs.
2. Make sure that the DIMMs are installed in matched
pairs. If the DIMMs are not installed in matched pairs,
reinstall them in matched pairs.
3. Make sure that the DIMMs are correctly seated. If
necessary, reseat the DIMMs.
4. Restart the blade server.
5. Remove and reinstall the DIMMs one at a time until
the failing DIMM is isolated. Replace the defective
DIMM.
If the problem remains, replace the system-board
assembly. Contact a service support representative for
assistance.
Note: For additional information about DIMMs, see
"Installing memory modules" on page 37.
1. Restart the blade server.
2. Remove and reinstall the DIMMs one at a time until
the failing DIMM is isolated.
3. Replace the defective DIMM.
Note: For additional information about DIMMs, see
"Installing memory modules" on page 37.
Make sure that all the DIMMs in the blade server are
supported. Replace all the unsupported DIMMs.