#7 Installing through the ceiling vent
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass through.
CAuTION
Keep combustible materials (such as grass, leaves, etc.) at
least 3 feet away from the flue outlet on the outside of the
building.
Fig. 17
11
pC 45 Corn/pellet Stove
storm collar
ashing
1" MIN.
1" MIN.
1" MIN.
No insulation or other
combustible materials
are allowed within 3"
of the PL vent pipe.
1" MIN.
min. wall to outlet
12"
venting
Minimum flue vent configuration
It is recommended that outside
air be installed with this venting
configuration.
Fig. 16
dO NOT INSTAll A FluE dAmPEr IN ThE EXhAuST
vENTINg SYSTEm OF ThIS uNIT.
dO NOT CONNECT ThIS uNIT TO A ChImNEY FluE
SErvINg ANOThEr APPlIANCE.
INSTAll vENT AT ClEArANCES SPECIFIEd bY ThE
mANuFACTurEr
STOvE IS hOT whIlE IN OPErATION. KEEP
ChIldrEN, ClOThINg, ANd FurNITurE AwAY.
CONTACT mAY CAuSE SKIN burNS.
!