Harman P35i Owner's Manual

Harman P35i Owner's Manual

Pellet insert
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
P35i Pellet Insert
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
!
Tested and approved for wood pellets only burning of
any other type of fuel voids your warranty. When burning
higher ash content pellets more frequent cleanings may
be required.
Save These Instructions
Owner's Manual
Installation and Operation
CAUTION
CAUTION
Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
WARNING
WARNING
3-90-775

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P35i and is the answer not in the manual?

Questions and answers

Summary of Contents for Harman P35i

  • Page 1 To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com Tested and approved for wood pellets only burning of Pour obtenir une traduction française de ce manuel, s’il any other type of fuel voids your warranty. When burning vous plaît contacter votre revendeur ou visitez www. higher ash content pellets more frequent cleanings may harmanstoves.com be required. Save These Instructions Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 2: Table Of Contents

    A. Mobile Home Installation ......17 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 3: Welcome

    INK: Black Background (1) Hole = Ø.30 352 Mountain House Road Hole location from side edge - 8.875 Halifax, PA 17032 Hole location from Btm edge - .9735 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 4: Listing And Code Approvals

    This appliance is equipped with 5mm mirrored ceramic instructions in this manual. glass. Replace glass only with 5mm mirrored ceramic glass. Please contact your dealer for replacement glass if needed. D. Electrical Rating 120 VAC, 60 Hz, 3.6 Amps (Start-up); avg. 1.5 Amps (Normal Run) Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 5: Special Warnings And Notes

    NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 6: Getting Started

    • Do NOT connect this unit to a chimney flue servicing another appliance. Fire Hazard • Do NOT connect to any forced air distribution duct or • Do not operate appliance before system. reading and understanding the operating instructions. Installation and service of this appliance should be performed by • Failure to operate properly may qualified personnel. Hearth & Home Technologies recommends cause a house fire. HHT Factory Trained or NFI certified professionals. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 7: Component Locator

    Viewing Glass Control Panel Return Air Slots Door Latch Ash Pan Cover Combustion Blower Exhaust Sensing Probe (ESP) Feed Motor Distribution Blower Ash Pan Latch Feeder Frame Latch 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 8: Pre-Use Checklist

    Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) 04/17 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 9: Dimensions And Clearances

    Dimensions and Clearances A. Appliance Dimensions 9-1/4” (235mm) Glass 24” 610mm Standard Surround Oversized Surround #1-00-774221 #1-00-774250 22” 40" (1016 mm) 46" (1168 mm) 559mm 31" (787 mm) 34" (864 mm) 2” 50mm 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 10: Clearances To Combustibles

    Hearth extension must be of a non-combustible material. It must extend beyond the appliance according to the measurements listed. Minimum Size Hearth Extension is 16" Deep By 32" Wide. The Maximum mantel depth (J) is 12" (305mm) with a minimum vertical height (K) of 12" (305mm). Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 11: Factory Built Fireplace

    PERSON PRIOR TO REUSE AS A CONVENTIONAL FIREPLACE. Additionally, the firebox floor of the ZC Wood or Gas Fireplace may be removed down to the outer metal shell of the fireplace if kit 1-00-574305 is used. The kit includes installation instructions and all materials needed to remove the firebox floor and still maintain a safe, compliant installation. Be certain to contact local code enforcement officials before beginning any modifications, as they may not be reversible in many cases. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 12: Vent Information

    G. The clearance to an inside corner is 12". NOTE: In Canada, where passage through a wall or partition of combustible construction is desired, the H. A vent must not be installed within 3 feet (914mm) above installation shall conform to CAN/CSA-B365. a gas meter/regulator assembly when measured from the horizontal center-line of the regulator. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 13: Avoiding Smoke And Odors

    The outside air kit consists of a flue stub pipe, fiberglass specific requirements for such an installation. gasket, silicone gasket, intake box and a section of flex pipe. Do not connect this unit to any air distribution duct An adjustable chimney intake extension, part # 1-00-674104 or system. is available to be used on masonry chimneys only. To install outside air, use kit part number 1-00-774280. Follow the installation instructions provided with the kit. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 14: Venting Requirements & Restrictions

    • Part #1-00-574034 is for use with 4” PL vent starter pipe of CAN/ULC-S635, Standard for Lining Systems for and 4” stainless steel flex pipe (Part #1-00-574034). Existing Masonry or Factory Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 15: Existing Fireplace Installation

    Non-combustible Insulation Sealing Plate When using single wall flex, this section of venting must be wrapped with non-combustible insulation to prevent excessive heat build-up in the cavity. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 16: Rear Venting

    Mortar can be used to give a Vent pipe seams must be more finished look. accessible. Zero Clearance Cabinet shown with Flue Rough-in Support Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 17: Mobile Home - (Us Only)

    The installer will need to determine and obtain the properly sized lag bolts and masonry anchors. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 18: Appliance Set-Up

    Now that the mounting frame is removed from the skid the frame, firmly grab the stove and pull it toward you and you can now install the surround panels. Note: Installation out away from the frame. Set unit to the side, Figure 8.3. instructions for the surround are located inside the box with Note: This may take 2 people to achieve. the surround panels. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 19: Control Board Installation

    1/2” jack bolts. Install the mounting frame into the opening and adjust these bolts to insure the ROUTE POWER CORD AWAY FROM THE APPLIANCE. frame is level, Figure 8.7. DO NOT RUN THE CORD UNDER OR IN FRONT OF THE APPLIANCE. Note: The use of all 4 leveling bolts may not be necessary. Tighten the 1/2" jack bolts against the lintel. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 20: Installing The Venting

    • On an interior wall next to or in place of a typical wall thermostat. • On the leg of a coffee table or end table in your favorite sitting location. • Sticking out through the punched hole at the lower right corner of the control panel. Note: When installing the room sensor externally, limit the Note: When installed in a rear vent configuration, the maximum distance from the stove to 25 feet or less. BTU may be reduced due to elevated ESP temperatures associated with the horizontal exhaust stream. Figure 8.10 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 21: Flame Guide Extension

    Notice the bend points away from the Heat Exchanger. Heat Exchanger Steel Flame Guide Extension Bends away from heat Exchanger Cast Flame Guide Burn Pot Figure 8.14 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 22: Operating Instructions

    FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE". 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 23: General Operating Information

    Fahrenheit. It also allows you to adjust monitor supplied to Harman ® the stove temperature while in "Constant Burn" Dealers exclusively. Mode using the inner scale marked from 1 to 7. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 24 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 25: Before Your First Fire

    -0.35". If necessary, adjust the draft voltage using the low draft adjustment screw on the control board (See The optimal method of operation is in Room Temp Page 24). Clockwise will increase the draft and counter- mode, with the Ignition switch set to Automatic. clockwise will decrease it. • Once set, record the low draft reading here:___________ -W.C. • Be sure and turn off of "Test" mode. Disconnect the draft meter and return the tube cap onto the draft tube. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 26: Starting A Fire In "Automatic" Mode

    OIL. • DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE. Keep all such liquids well away from the heater while it is in use, combustible materials may ignite! 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 27: Service & Maintenance

    Shock and Smoke Hazard • Turn unit to the off position, let appliance completely cool and combustion blower must be off. Now you can unplug appliance before servicing. • Smoke spillage into room can occur if appliance is not cool before unplugging. • Risk of shock if appliance not unplugged before servicing appliance. Follow the detailed instructions found in this section for each step listed in the chart below. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 28: Quick Reference Maintenance

    Brush & vacuum venting system combustible container with tight fitting lid outside. * A flue brush of appropriate size and length may need to be purchased for proper maintenance. 1. Protective gloves will help prevent skin abrasion while working on steel surfaces. 2. Frequency of cleaning depends largely on fuel type. Lower quality pellets require most frequent cleaning. 3. Flame resistant gloves will help protect your skin from potential contact with heat or flames. 4. Yearly cleaning is also known as a Total Clean. This requires completing all the Daily, Weekly, Monthly and Yearly maintenance mentioned. This should be done before you begin burning the unit each heating season. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 29: General Maintenance Procedure

    Do not use the ash container for other debris or yard waste. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 30 Loosen the two wingscrews located on the front of the burn pot housing. b. Lift the cover off of the wingscrews and set aside. c. Using your ash-vac, remove any ashes or debris from the air chamber. d. You can tap on the igniter, located above the cleanout hole. This will help to remove any accumulation on the igniter element. e. Re-install the cleanout cover and tighten the wingscrews. Be sure that the cover is completely covering the hole, as air leakage here may lead to incomplete combustion or poor ignition. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 31 Whenever the hopper is empty, inspect and remove any large amounts of sawdust or fines. Although this i. Release the spring latches and slide the insert body out finer material will mostly feed through with the fuel, large onto the hearth or onto the service rail kit, if purchased. quantities of sawdust may restrict feeder flow. j. Remove the exhaust chamber access cover on the right rear of the insert. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 32 GLASS DOOR REMOVED, CRACKED, BROKEN, OR SCRATCHED. Retainers and screws Glass Adhesive gasket Door Frame CAUTION Handle glass with care. When cleaning door glass; • Avoid striking, scratching, or slamming glass. • Do NOT Clean Glass When Hot. • Do NOT use abrasive cleaners. • Inspect gasket, replace if necessary. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 33: Motors & Components

    Ash Pan Cover Door Latch Control Panel Return Air Slots Combustion Blower Exhaust Sensing Probe (ESP) Feed Motor Distribution Blower Pellet Pro Feeder Ash Pan Latch Frame Latch Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 34 • Slide the insert body out of the mounting frame. • Locate the combustion blower motor in the back right corner. • Loosen 3 wing screws and turn the blower and mounting plate 1/4 turn. • Lower the motor and paddle fan out of the blower housing. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 35 • Slide the insert body out of the mounting frame. • Locate the feeder cover from the right side of the unit. • Loosen the wing nut approximately 3/4 of the way out on the stud. • Pull out on the bottom of the cover then lift upward to remove. • Notice the deflector shield is sitting loose in the feeder. It can be removed by rolling it from under the pusher Vacuum fines from this area arm shaft. Just be sure it is repositioned properly. • When re-installing cover, tighten the wing nut hand tight only. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 36 Only the first few inches of the wires are insulated for high temperatures. These insulated wires are all that can be inside the feeder or burn pot. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 37: Reference Materials

    Reference Materials A. Wiring Diagram Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 38: Loss Of Power

    3. Add firestarter to pellets following manufacturer’s flash a six-blink status error. (See ESP error codes) instructions. • If the fire is still burning, it will resume normal 4. Light pellet gel with a match, and close the door, turn Mode operation. Selector to Constant Burn. Operation will begin when the fire reaches the proper temperature. Contact your dealer if you have questions about UPS compatibility with your appliance. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 39: Troubleshooting

    Check operation in "Test" mode, Clear obstruction Failed feed motor Replace motor if necessary Fire isn't hot enough for blower operation Increase temperature setting When operating in Disabled / Constant Burn Mod, Disabled / Constant Burn the blower will not run below a #3 setting on the No Distribution Blower temperature dial. Increase temperature setting Failed motor or connection- "Test" mode Check connections / Replace blower Feed Limit too low Set Feed Limit at #4 or higher Low heat output, or room temperature Room sensor reports the room air temperature to Room sensor location different than doesn't match the control board. Move sensor location or adjust thermometer location thermometer or other set pint accordingly. readings Excessive ash buildup on heat exchanger Clean exhaust, firebox and heat exchanger or in the exhaust thoroughly Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 40: Service Parts Lists

    Gasket Set, Burnpot/Pipe Stub Set of 5 1-00-07384 Mounting Frame Assembly 1-10-774235A Screw - HCS 5/16-18 X 1-1/4 Pkg of 50 3-30-1129-50 Additional service parts on following page. 2/19 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 41 Pkg of 25 1-00-015605 Circuit Board Plate 1-10-774114A Pre HF662201 3-20-23705-5 5 Amp Fuses, Pkg of 5 Post HF662201 1-00-05237 Control Panel Sticker 3-90-07766 Additional service parts on following page. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 42 Wingscrews, 1/4-20 x 5/8 Pkg of 10 3-31-782108-10 Flame Guide 3-00-03000 Flame Guide Extension 1-00-774338 Cleanout Cover Set Left & Right 1-00-774213 Additional service parts on following page. 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 43 3-30-1104-100 Roller Hardware 4 Sets 1-00-05232 Room Sensor 3-20-00906 Pre 008654714 3-42-1990 Touch up Paint, Black Post 008654714 3-42-19905 Wiring Harness 3-20-08727 Additional service parts on following page. Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 44 3-30-8005-100 28.19 Grommet-1/2 in ID-Thick Pkg of 12 3-31-2761-12 28.20 Gasket Hopper Throat 3-44-677185 Gasket, Snout Pkg of 10 3-44-677160-10 Hopper Switch Feeder Fitting Pkg of 2 1-00-142818 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 45: Custom Surround Sizes

    Part #: 1-00-774221-SPL Arched - Minimum Center Height Rectangular Minimum Height Arched - Minimum 31-3/8” Side Height 797 mm 28-7/8” 733 mm 24-7/8” 632 mm Minimum Width - 40" 1016mm Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 46: Warranty Policy

    (engine, inner cover,access cover and fireback) None 1 Year All replacement parts beyond warranty period See conditions, exclusions and limitations on the next page Page 1 of 2 4021-645K 1/20 3-90-775 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20...
  • Page 47 OTHER THAN THE WARRANTY SPECIFICED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645K 1/20 Page 2 of 2 Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...
  • Page 48 ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ NOTICE SAVE THESE INSTRUCTIONS • • • Read, understand and Leave this manual with Important operating follow these instructions party responsible for and maintenance for safe installation and use and operation. instructions included. operation. Printed in U.S.A Save These Instructions Harman® • P35i Owner's Manual_R58 • 2010 - ___ • 01/20 3-90-775...