Installation - Harman 300i Woodburning Fireplace Insert Installation & Operating Manual

Woodburning fireplace insert
Hide thumbs Also See for 300i Woodburning Fireplace Insert:
Table of Contents

Advertisement

For Installation In Masonry Fireplace Only
Fireplace / Opening Requirements; Masonry fireplace ONLY.
dimension
A
Minimum Width
b
Minimum Depth
C
Minimum Height*
d
Minimum Hearth Height**
E
Minimum Hearth Depth
*hEIghT mEASurEmENT dOES NOT ACCOuNT FOr FlOOr
PrOTECTION mATErIAl whICh mAY bE NECESSArY.
**FlOOr PrOTECTION rEQuIrEmENTS ChANgE wITh hEArTh
hEIghT bElOw 6" (152 mm). SEE PAgE 13.
Floor Protection requirements;
raised hearth 6" (152 mm) or higher-
The depth of the masonry hearth must measure a minimum
of 12.5 inches (318 mm) from the face of the fireplace
opening, to support the insert body. Depending on the
overall depth of the hearth, additional floor protection may
be necessary. If the depth of the hearth measures 25.5
inches (648 mm) or more, from the fireplace facing, no
additional floor protection is needed. If the hearth depth is
less than 25.5 inches (648 mm), floor protection must be
installed.
Floor protection in front of the raised hearth must be a
minimum 3/8" (9.5 mm) of 0.84k material. An R value of
0.45 or higher is also acceptable. The standards call for
floor protection to extend a minimum of 18 inches (457 mm)
in front of the appliance door opening, and 8 inches (200
mm) to each side.
NO AddITIONAl FlOOr PrOTECTION rEQuIrEd.
25.5"- 648 mm
18"-457mm
11

Installation

Inches
Millimeters
28.5
724
18
457
24
610
6
152
12.5
318
B
A
E
Top View
8"
200 mm
18" (457mm)
AddITIONAl FlOOr PrOTECTION IS rEQuIrEd.
25.5"- 648 mm
18"-457mm
FlOOr PrOTECTION
Harman 300i Wood Insert
C
D
8"
200 mm
3-90-300101R11_05/14