Harman TL 2.0 Owner's Manual

Harman TL 2.0 Owner's Manual

Non-catalytic, top load, wood burning room heater
Hide thumbs Also See for TL 2.0:

Advertisement

Owner's Manual
Installation and Operation
Model:
TL2.0
Non-Catalytic, Top Load,
Wood Burning Room Heater
Item #1-90-856000
Contact your local dealer with questions on installation,
operation or service.
Important operating and
maintenance instructions
included.
!
PLEasE REad THIs ENTIRE MaNuaL
BEfORE INsTaLLaTION aNd usE Of
THIs WOOd-BuRNINg ROOM HEaTER.
f a I L u R E T O f O L L O W T H E s E
INsTRuCTIONs COuLd REsuLT IN
PROPERTy daMagE, BOdILy INjuRy
OR EvEN dEaTH.
• dO NOT sTORE OR usE gasOLINE OR OTHER
fLaMMaBLE vaPORs aNd LIquIds IN THE
vICINITy Of THIs OR aNy OTHER aPPLIaNCE.
• Do not overfire - if any external part
sTaRTs TO gLOW, yOu aRE OvERfIRINg. CLOsE
aIR CONTROLs. OvERfIRINg WILL vOId yOuR
WaRRaNTy.
• Comply with all minimum ClearanCes to
COMBusTIBLEs as sPECIfIEd. faILuRE TO
COMPLy May CausE a HOusE fIRE.
!
TEsTEd aNd aPPROvEd fOR usE WITH dRy,
sEasONEd CORdWOOd ONLy. dO NOT BuRN WET
OR gREEN WOOd. BuRNINg aNy OTHER TyPE Of
fuEL WILL vOId yOuR WaRRaNTy.
Save These Instructions
dO NOT dIsCaRd THIs MaNuaL
Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
CAUTION
NOTICE
Leave this manual with
party responsible for use
and operation.
HOT, WILL CausE BuRNs.
• Do not touCh glass until it is CooleD
• never allow ChilDren to touCh glass
• Keep ChilDren away
• Carefully supervise ChilDren in same
ROOM as fIREPLaCE.
• alert ChilDren anD aDults to hazarDs of
HIgH TEMPERaTuREs.
HIgH TEMPERaTuREs May IgNITE CLOTHINg
OR OTHER fLaMMaBLE MaTERIaLs.
• Keep Clothing, furniture, Draperies anD
OTHER fLaMMaBLE MaTERIaLs aWay.
CHECk BuILdINg COdEs PRIOR TO INsTaLLaTION.
• installation must Comply with loCal, regional,
sTaTE aNd NaTIONaL COdEs aNd REguLaTIONs.
• Consult loCal builDing, fire offiCials or
a u T H O R I T I E s H av I N g j u R I s d I C T I O N a B O u T
REsTRICTIONs, INsTaLLaTION INsPECTION, aNd
PERMITs.
3-90-08560
Wood Stove
Use & Care Video
!
WARNING
HOT suRfaCEs!
g L a s s a N d O T H E R
s u R fa C E s a R E H O T
duRINg OPERaTION aNd
COOL dOWN.
!
CAUTION
Rev: 8
October, 2013

Advertisement

Table of Contents
loading

Summary of Contents for Harman TL 2.0

  • Page 1 Wood Stove Use & Care Video Owner's Manual Installation and Operation Model: TL2.0 Non-Catalytic, Top Load, Wood Burning Room Heater Item #1-90-856000 Contact your local dealer with questions on installation, operation or service. NOTICE dO NOT dIsCaRd THIs MaNuaL • •...
  • Page 2: Tl2.0 Woodburning Stove

    This unit is approved for cooking using Harman grill #1-00-08121 - KEEP BYPASS DAMPER OPEN. Cet appareil est aussi approuvé pour utiliser la grille de cuisson Harman # 1-00-08121 - L'AMORTISSEUR DE DÉVIATION DOIT ÊTRE OUVERT REFER TO PRODUCT MANUAL FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS.
  • Page 3: Table Of Contents

    TL2.0 Woodburning Stove TaBLE Of CONTENTs section 1: Listing and Code approvals section 9: service & Maintenance A. Appliance Certifications A. Soot Formation (Removal) B. Mobile Home Approval B. General Maintenance Procedures C. Glass Specifications D. Electrical Rating section 10: Reference Materials E.
  • Page 4: Section 1: Listing And Code Approvals

    TL2.0 Woodburning Stove Listing and Code approvals a. appliance Certification e. btu & efficiency specifications Model: TL2.0 Woodburning Stove Particulate Emissions Laboratory: OMNI-Test Laboratories, Inc. 2.6g/hr Avg Rating: Report No. 135-S-29-2 Type: Solid Fuel Room Heater / Wood *BTU Input: 9,600 - 31,800 / hr Burning Type. Heating Capacity: 1,600-1,900 sq.
  • Page 5: Section 2: Special Warnings And Notes

    TL2.0 Woodburning Stove special Warnings and Notes Carbon monoxide, referred to as CO, is a colorless, CO detectors are very sensitive and may sound an alarm odorless gas that is produced during combustion of wood for fumes other than CO or CO from sources other than and other fuels.
  • Page 6: Section 3: Getting Started

    TL2.0 Woodburning Stove getting started a. design, Installation & Location Considerations B. fire safety 1. appliance Location Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain Consideration must be given to safety, convenience, traffic the designated air space around the chimney.
  • Page 7: Component Locator

    TL2.0 Woodburning Stove C. Component Locations Top Load Door Top Load Opening Bypass Damper Control Handle Front Load Door Bolt-Down Holes for Mobile Home Installations Air Control Ash Door Front Load Door Latch Ash Door Latch Save These Instructions Dry Seasoned Wood Only! 3-90-08560...
  • Page 8: Pre-Use Checklist

    TL2.0 Woodburning Stove d. Pre- use Check List Place the appliance in a location near the WARNING final installation and follow the procedures below: INsPECT aPPLIaNCE aNd COMPONENTs Open the appliance and remove all articles fOR daMagE. daMagEd PaRTs May packed inside.
  • Page 9: Section 4: Dimensions & Clearances

    9.1" (231mm) 23.9" (665mm) Centered Weight..........452 lbs The Harman TL2.0 meets the U.S. Environmental Protection Agency’s emission limits for wood heaters Flue Size........6 inch sold after July 1, 1990. Log Length Recommended... 18" Average Emissions.......2.6 Grams Per Hr. Outside Air size......4.5 inch I.D.
  • Page 10: Clearances To Combustibles

    TL2.0 Woodburning Stove b. Clearances to Combustibles vertical venting Configuration Location single-wall Pipe Double-wall pipe unit to side Wall 14" / 356 mm 14" / 356 mm unit to Back Wall 13" / 330 mm 7" / 178 mm vent Pipe to side Wall 24" / 610 mm 24"...
  • Page 11 TL2.0 Woodburning Stove vertical venting Configuration - horizontal exit Location single-wall Pipe unit to side Wall 13" / 330 mm unit to Back Wall 13" / 330 mm vent Pipe to side Wall 23" / 584 mm vent Pipe to Back Wall 18" / 457 mm vent Pipe to Ceiling 16"...
  • Page 12: Floor Protection

    TL2.0 Woodburning Stove C. floor Protection Requirements Minimum Size floor protection (USA) is 48" Deep By 32.5" Wide. floor Protection Inches Millimeters Requirements Sides- USA /CANADA * Front- USA /CANADA * Rear- USA Rear- CANADA Wall Wall * Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States.
  • Page 13: Draft

    For details on the other three The Harman TL2.0 may be installed with a minimum (.6 mm) options, refer to the most recent edition of the NFPA 211 code.
  • Page 14: The Chimney

    TL2.0 Woodburning Stove Non-combustible cover, one side only. If two covers are Closest Combustible Material Hole with minimum used, each must be mounted clearance of 18” on non-combustible spacers Minimum 2” (50mm) (450mm) Between at least 7/8” (21mm) away Clearance to Brick connector and wall.
  • Page 15 TL2.0 Woodburning Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have Chimney liner it thoroughly inspected and cleaned. Any faults which make inner edges the chimney unsafe and unusable must be repaired prior to use.
  • Page 16: Chimney Connector

    TL2.0 Woodburning Stove standard Ceiling Installation with factory Built Chimney Chimney Cap Chimney storm Collar sections Roof flashing Roof Radiation shield attic Radiation shield Minimum air space Chimney with Chimney support Listing Chimney Connector The Chimney Connector shall Not Pass Through an attic or Roof space, Closet or similar Concealed space, a floor or Ceiling.
  • Page 17 TL2.0 Woodburning Stove Cathedral Ceiling Installation with factory Built Chimney Chimney Cap Roof Radiation Factory-Built Shield Metal Chimney Sealed Storm Collar Roof Flashing Cathedral Style Chimney Support Finishing Collar Chimney Connector Save These Instructions Dry Seasoned Wood Only! 3-90-08560...
  • Page 18 TL2.0 Woodburning Stove Chimney breach fireplace Conversion with non-Combustible wall Minimum clearance to unprotected ceiling 15” Chimney connector sealed at thimble Flue liner with required air space Airtight insulated Minimum of three sheet clean-out metal screws per joint of chimney connector Mantel and trim protection Floor Protection* Damper closed and sealed with non-combustible...
  • Page 19 TL2.0 Woodburning Stove Chimney breach fireplace Conversion with Combustible wall 1” Clearance for exterior chimney or 2” clearance for interior chimney and 2” clearance for NFPA 211 - type approved thimbles Flue liner with required Minimum clearance from chimney air space connector to uprotected ceiling 15” Listed or approved thimble assembly Combustible Wall...
  • Page 20: Mobile Home Installation

    TL2.0 Woodburning Stove mobile home a. mobile home installation NOTE: The top sections of the chimney must be removable to allow a maximum clearance of 13.5 feet (411cm) from mobile home approval - u.s. only. ground level for transportation purposes. dO NOT INsTaLL IN a MOBILE HOME IN CaNada. 1.
  • Page 21: Section 7: Appliance Set-Up

    TL2.0 Woodburning Stove appliance set-up a. Outside air attachment B. Leveling the appliance Parts and Supplies Needed: Kit #1-10-856082, 1 piece of Use metal shim material under the pedestal base where metal flexible pipe, 4" X needed length. 1 Rodent Screen, needed for leveling.
  • Page 22: Optional Blower Kit

    TL2.0 Woodburning Stove d. Optional Blower Installation E. Top air grill Option use ONLy Blower Part #1-00-856002 With This The top air grill installs over the flue collar and simply appliance. rests on the top of the stove. The brushed stainless grill is included with this option as well.
  • Page 23: Section 8: Operating Instructions

    TL2.0 Woodburning Stove Operating Instructions B. general Operating Information CAUTION 1. draft Before you install and/or operate your wood stove, please read the entire contents of this manual. Pay particular attention approved for use with wood fuel only. The use of any to the explanation of draft and its effect on stove performance in other fuel will void the product warranty and may the Installation section.
  • Page 24: Burning As A Fireplace

    This appliance has been tested and approved for burning as it is used to revitalize the fire at the rear of the firebox. The an open fireplace. To do so, a spark screen (Harman part# remainder is delivered into the "Firedome Plus" combustion 3-40-06960;...
  • Page 25: User Controls

    TL2.0 Woodburning Stove E. user Controls For low burn, slide the air control to the left. For medium burns, use notches 1 to 2. Maximum heat is attained with Two important controls - the damper bypass handle and the the air control all the way to the right. Do not burn the stove air control lever regulate the operation and output of the stove.
  • Page 26 TL2.0 Woodburning Stove Providing you have the charcoal bed described, close the dIsPOsaL Of asHEs; bypass damper by pulling the handle toward the front of the ashes should be placed in a steel container with a tight fitting lid. The container of ashes should stove.
  • Page 27: Section 9: Service & Maintenance

    TL2.0 Woodburning Stove solid fuel burning spave heaters must be cleaned regularly, service & Maintenance as soot, ash and creosote may accumulate. Creosote- formation and Need for Removal; When properly maintained, your stove will give you many years of trouble-free service. Contact your dealer to answer When wood is burned slowly, it produces tar and other questions regarding proper operation, trouble-shooting and organic vapors which combine with expelled moisture service for your appliance.
  • Page 28: General Maintenance Procedures

    Do not operate the stove with a broken glass. Replacement glass, which is ceramic glass, should be obtained only through your Harman dealer. To replace a broken glass; first be sure to carefully remove the broken glass and any remaining shards or pieces. With...
  • Page 29 TL2.0 Woodburning Stove 3. firebox 5. Chimney Connector • frequency: As necessary / Yearly • frequency: As necessary / Yearly • By: User • By: Qualified Service Technician / User Cleaning the firebox and internal heat exchange surfaces is At the end of the burn season, brush and clean all sections recommended to maintain thermal efficiency.
  • Page 30: Section 10: Reference Materials

    TL2.0 Woodburning Stove Reference Materials Dry Seasoned Wood Only! 3-90-08560 Save These Instructions...
  • Page 31: Service Parts Listing

    TL2.0 service Parts Beginning Manufacturing date: sept 2011 Wood stove Ending Manufacturing date: active 1-90-856000-1 Black W/Pedestal part number list on following page. 11/13...
  • Page 32 TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 33 TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 34: Epa Hang Tag

    TL2.0 service Parts Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 35: Warranty Policy

    Manufactured by: HeartH & HoMe tecHnologies, inc. Model: tl2.0 u.s. enviroMental Protection agency Meets EPA particulate matter (smoke) control requirements for noncatalytic wood heaters built on or after July 1, 1990. sMoKe grams Per Hour efficiency 100% Wood heaters with higher efficiencies cost less to operate. Heat outPut 9,600 to 31,800 btu use this to choose the right size appliance for your needs.
  • Page 36 Hearth & Home Technologies LIMITEd LIfETIME WaRRaNTy Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WaRRaNTy COvERagE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 37 WaRRaNTy CONdITIONs: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 38 TL2.0 Woodburning Stove service & Maintenance Log Date Of Service Performed By Description Of Service Save These Instructions Dry Seasoned Wood Only! 3-90-08560...
  • Page 40 At Harman, we build each product to a standard, not a price. This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.

Table of Contents