Harman Accentra 52i Pellet Insert Installation Manual
Harman Accentra 52i Pellet Insert Installation Manual

Harman Accentra 52i Pellet Insert Installation Manual

Hide thumbs Also See for Accentra 52i Pellet Insert:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
Accentra 52i Pellet Insert
!
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
1
Installation Manual
Installation and Appliance Setup
CAUTION
CAUTION
Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
WARNING
WARNING
3-90-00574i

Advertisement

Table of Contents
loading

Summary of Contents for Harman Accentra 52i Pellet Insert

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions vous plaît contacter votre revendeur ou visitez www. and installation inspection requirements in your area. harmanstoves.com Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 2: Table Of Contents

    J. Fire Safety ........20 K. Inspect Appliance & Components ....20 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 3: Installation Standard Work Checklist

    ________________________________ Appliance Setup Section 5 (Pg. 20-21) All packaging and protective materials are removed. ________________________________ Accessories installed properly. ________________________________ Manual bag and all its contents are removed from inside the appliance and given to party responsible for use and operation. ________________________________ Started appliance and verified that all motors and blowers operate as they should. ________________________________ Hearth and Home Technologies recommends the following: Photographing the installation and copying this checklist for your file. This checklist remains visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 4: Product Specific And Important Safety Information

    T H E S T R U C T U R A L I N T E G R I T Y O F T H E MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 5: Non-Combustible Materials Specification

    • Disable safety switches Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 6: Getting Started

    • Avoid outside wall Windward Leeward Multi-level Roofs Recommended: NOT recommended: Outside Air Intake Outside Air Intake on windward side on leeward side Figure 2.1 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 7: Tools And Supplies Needed

    WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 8: Clearances

    Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. 24-7/8” 14-3/8” 12-3/4” To Top Edge 27-5/8” 10-1/2” To Glass 13/16” 14-3/8” 15-9/16” 41-13/16” 29-15/16” Figure 3.1 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 9: Clearances To Combustibles & Floor Protection

    CLEARANCES: (From Glass) From Insert Body: 12” 12” 0” 0” 6” (305mm) (305 mm) (152 mm) *3/4” trim, zero clearance to cast surround 18” 457mm (Canada) Figure 3.2 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 10: Termination Location And Vent Information

    Mineral wool or an equivalent non combustible insulation is DO NOT REMOVE BRICKS OR MORTAR FROM THE used on top of the plate to reduce EXISTING FIREPLACE. the possibility of condensation. Insulation alone should not be used to seal the damper opening. Figure 4.2 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 11 36” CAUTION KEEP COMBUSTIBLES (SUCH AS GRASS, LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE 12” min. OUTLET ON THE OUTSIDE OF THE BUILDING. Figure 4.4 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 12 Figure 4.5 Note: If the Harman® Accentra 52i Pellet Insert is installed into a factory built wood burning fireplace, this label (Harman® part #3-90-674204) MUST be attached to the altered fireplace. This label is included in the Manufactured fireplace installation kit.
  • Page 13 Installing the Accentra 52i Pellet Insert into a Harman Zero Clearance Cabinet If you don’t have a factory built fireplace or masonry fireplace, the Accentra 52i Pellet Insert can also be installed into the Harman Zero Clearance Cabinet, Part # 1-00-574323. This is the only permissible way to install the Accentra 52i Pellet Insert without a suitable fireplace. After the Harman Zero Clearance Cabinet is installed, type PL vent pipe, wall pass-throughs and terminations are used (Note: Flex pipe is not approved these types of installation). Detailed installation instructions are included with the Zero Clearance Cabinet. These same installation instructions can also be found on-line at www.harmanstoves.com. Below are two sample installations using the Harman Zero Clearance Cabinet. Harman Zero Clearance Cabinet Requirements for Terminating the Venting through an Exterior Wall. The clearance to a window or door that may be opened must be a minimum of 48" to the side and 48" below the window/ door, and 12" above the window/door. (with outside air installed, 12”...
  • Page 14: Venting & Use Of Elbows

    Any use of horizontal venting will require more frequent cleaning. It is the responsibility of the installer to make sure the entire flue configuration is accessible for cleaning. 4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built wood burning fireplaces with class A metal chimneys. All pellet vent pipe must be secured together either by means provided by pipe manufacturer or by 3 screws at each joint. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 15: Battery Back-Up Power

    CAUTION Use only Harman® approved battery back-up devices. Other products may not operate properly, can create unsafe conditions or damage your appliance. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 16: Outside Air

    Record the second draft reading _______. If the second reading is more than .05” lower than the first reading, check Masonry Flue Liner for possible restrictions or the need for outside air. For more Masonry Chimney information on the draft test procedure, refer to the Low Draft Figure 4.8 section of this manual. Voltage Adjustments Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 17: Negative Pressure

    • Inadequate draft due to environmental conditions • Down drafts • Tight sealing construction of the structure • Mechanical exhausting devices Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 18 Chimneys and Vents, or CAN/ULC-S640, Standard for an air tight seal in most cases; however, in some cases a perfect seal is not achieved. For this reason and the fact Lining Systems for New Masonry Chimneys. that the Accentra 52i Pellet Insert operates with a positive vent pressure, we specify that the joints also be sealed with silicone. Where passing through an exterior wall or roof, be sure to use the appropriate pass-through device providing an adequate vapor barrier. Venting manufacturers generally provide these pas-through devices. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 19: Mobile Home Installation

    Roof Flashing 8. Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24. WARNING Asphyxiation Risk: Joist Shield/Firestop NEVER INSTALL INTO A SLEEPING ROOM Approved Class”L” or “PL” Pellet Vent Consumes oxygen in the room WARNING Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 20: Fire Safety

    MINIMUM LOW BURN RATE THAT MUST NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS TO ALTER THIS SETTING OR OTHERWISE OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 21: Appliance Setup

    Figure 5.2 Mounting Frame Ash Pan (2) Spring Latches (One on each side) The drawing above shows the major sub components of the Accentra 52i. Take notice as to where the spring latches are located. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 22: Beginning The Installation

    4. Tip the top of the heat exchanger toward the door ¼”-20 x3/8” opening until it can be lifted up and out. Figure 5.4a Flange Bolt Notch (See Note Below) ¼”-20 x 5/8” with ¼” Nut ¼”-20 x 5/8” with ¼” Nut Figure 5.6 Figure 5.4 Note: The wings mount on the rear side of the mounting frame flange Latch below the notch, and on the front side above the notch. Figure 5.4a Lifting tab Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 23 (NOTE: Use of all 4 leveling bolts may not be necessary.) connections. Tighten the ½” jack bolts against the lintel. See Figure 5.13. The flue stub assembly base is a round plate which allows it 1/2" threaded jack bolts & to swivel to allow the flue pipe to exit the mounting frame in coupler weldment and 1/4-20 x other positions rather than straight up. Figure 5.10. 5/8” Flange bolts Leveling bolt holes are outer, threaded holes. Anchor bolt holes are inner non-threaded holes Figure 5.13 Figure 5.9 Figure 5.10 Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i Anchor holes...
  • Page 24: Electrical Connection Installation

    Complete the following electrical connections There are 3 connections that must be completed. See Figures 5.18 & 5.19. The green wire with a female terminal is the stove body ground. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 25 Adjustment Tek screws Make sure door gap is even on both sides Figure 5.21 Figure 5.19 WARNING ROUTE POWER CORD AWAY FROM THE APPLIANCE. DO NOT RUN CORD UNDER OR IN FRONT OF THE APPLIANCE. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 26: Reminders

    Figure 5.22 Note: On models with porcelain finish, there may be some cases where the cast side panels come in contact with the Hopper lid foam cast wings. There are (4) #10 screws and flat washers gasket located on the hinge plates that can be used for adjustment. The washers can be removed to allow for less travel. Cast Top #10 Washer Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 27: Low Draft Voltage Adjustments

    _____ in. W.C. If the reading is higher, slowly turn the set screw counter-clockwise until the draft lowers. If the If the unit is not adjusted properly, it does not cause a safety reading is lower, very slowly turn the set screw clockwise concern. If the unit is adjusted too high, only efficiency is lost. until the draft increases. If the unit is adjusted too low, the low draft pressure switch will not allow the feeder motor or the igniter to operate. NOTE: In some cases, the draft may not go as low as -.35 even with the set screw completely counter-clockwise. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 28: Reference Materials

    RESULT IN A HOUSE FIRE. USE ONLY APPROVED service person. More frequent cleaning will be required. FUELS AND OPERATION GUIDELINES It is imperative that control compartments, burners, and circulating air passageways of this stove be kept clean. CAUTION DO NOT USE MAKESHIFT COMPONENTS OR OTHER COMPROMISES WHEN INSTALLING THIS APPLIANCE. Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 29: Wiring Diagram

    B. Wiring Diagram DISTRIBUTION BLOWER DISTRIBUTION BLOWER Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...
  • Page 30 352 Mountain House Road, Halifax, PA 17032 www.harmanstoves.com Please contact your Harman dealer with any questions or concerns. ® For the location of your nearest Harman dealer, ® please visit www.harmanstoves.com. Printed in U.S.A Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/15 3-90-00574i...

Table of Contents