Harman Accentra 52i Owner's Manual

Harman Accentra 52i Owner's Manual

Pellet insert
Hide thumbs Also See for Accentra 52i:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your local dealer with questions on installation, operation or service.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
Accentra 52i Pellet Insert
!
Tested and approved for wood pellets and shelled field
corn fuel only. Burning of any other type of fuel voids
your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
1
Owner's Manual

Care and Operation

CAUTION
CAUTION
Harman® • Accentra 52i Owner's Manual_R8 • 2013 -___ • 07/14
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
WARNING
WARNING
3-90-00574c

Advertisement

Table of Contents
loading

Summary of Contents for Harman Accentra 52i

  • Page 1: Care And Operation

    Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions vous plaît contacter votre revendeur ou visitez www. and installation inspection requirements in your area. harmanstoves.com Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 2: Welcome

    Date of Manufacture/Date de fabrication : 2013 2014 2015 JUL AUG SEPT OCT NOV DEC Manufactured by/Fabriqué par: Hearth and Home Technologies P.N. 3-90-00575 Rev C Harman Accentra 52i Pellet Insert Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 3: Table Of Contents

    H. Pellet Feeder Chamber ......22 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14...
  • Page 4: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 5: B. Limited Lifetime Warranty

    THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 6: Product Specific And Important Safety Information

    120 VAC, 60 Hz, Start 5.0 Amps, Run 4.0 Amps NOTE: Some generator or battery back-up systems may not be compatible with the micro-processor electronics on this appliance. Please consult the power supply manufacturer for compatible systems. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 7: General Information

    Contact your dealer for more information, or visit: www. hpba.org/safety-information. To prevent unintended operation when not using your stove for an extended period of time (summer months, vacations, trips, etc): • Unplug stove from receptacle. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 8: Control Explanation

    Harman® stove temperature setting, while in Stove Temp Mode, blower speed by turning the knob to the Dealers exclusively. using the inner scale marked from 1 to 7. high or low side of each mode. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 9: Fuel Specification

    Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 10: General Operating Information

    Pay particular attention to the fire protection and venting instructions. 2. Double check that the ash pan and firebox are empty! 3. Close the front door. Figure 3.1 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 11: Operating Instructions

    7-10 minutes. After this time, the igniter light should turn off and the unit should begin to operate per the settings at the control. Figure 4.2 Figure 4.3 Figure 4.4 Figure 4.5 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 12: Ignition Cycles

    When this happens, the unit will need to be turned to the off position and restarted. If needed, follow the instructions on “Starting Your First Fire” section of this manual. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 13: Automatic Ignition

    If, at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only at maximum burn rate and during normal operation, the ash bed will be larger. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 14: E. Automatic Ignition

    This setting will produce continuous maximum heat output with the distribution blower at full speed. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 15: Manual Ignition

    , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only at maximum burn rate and during normal operation, the ash bed will be larger. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 16: F. Manual Ignition

    NOTE: During the use of this mode, if you keep increasing the temperature dial setting to increase the fire size, the distribution blower will automatically come on when the ESP Temperature reaches 350° F, or 81% output. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 17: Proper Shutdown Procedure

    NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of ash at the recommended interval or you see soot coming from the vent. Not properly cleaning your appliance on a regular basis will void your warranty. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 18: Glass Maintenance

    In any case, dry thoroughly before relighting your stove. Replace glass only with high temperature ceramic glass. Inspect door gasket during cleaning and inspection Glass Gasket Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 19: Burnpot Maintenance

    Note: The hot lead/cold lead connection must always be pulled to the rear of the feeder body before operation. Igniter hot lead wires (High temperature) Figure 5.3 Viewed from below through the ash pan opening. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 20: Heat Exchanger Maintenance

    4. Tip the top of the heat exchanger toward the door opening until it can be lifted up and out. Figure 5.5a Brush the firebox free of remaining Fly-Ash. Figure 5.7 Figure 5.5 Latch Figure 5.5a Lifting tab Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 21: Combustion Blower Chamber

    Figure 5.11. Lower Combustion Chamber Combustion Cover Assembly Figure 5.9 Upper Combustion Chamber Figure 5.11 Combustion Cover Latch Figure 5.10 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 22: Pellet Feeder Chamber

    NOTE: views are shown with the exhaust tube and covers removed for better viewing. Feeder clean out cover 5/16" Wing Nut Figure 5.13 Pellet Metering Possible pellet fines Slide Plate buildup area. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 23: Troubleshooting And Frequently Asked Questions

    5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light within the 36 minute start cycle. To reset - Turn Mode Selector to "OFF", then turn to either mode again.) Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 24: Frequently Asked Questions

    7. This is normal. Flame will settle down once the fire is established. Contact your dealer for additional information regarding operation and troubleshooting. visit www.harmanstoves. com to find a dealer. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 25: Troubleshooting

    1. No fuel in hopper. 2. Draft is too low, blocked flue. 3. Something is restricting fuel flow. 4. Feed motor or combustion blower has failed. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 26: Reference Materials

    If a fire occurs, call the fire department, shut down the stove, and evacuate the residence. Before using the appliance, have the venting system thoroughly inspected and replace any damaged components. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 27: Motor And Component Location

    In the event of component failure, replace component(s) equivalent to the original. See Service Parts section of this manual. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 28: Loss Of Power

    Contact your dealer if you have questions about UPS compatibility with your appliance. Harman® Surefi re 512H Battery Back-up The 512H connects to a 12 volt deep cycle battery that will run your appliance for up to eight (8) hours. It includes a trickle charge feature that keeps your battery charged when power is available.
  • Page 29: Service Parts

    22” Hopper: 24” Hopper: 1-90-574200-1 (Black) 1-90-574220-1 (Black) 1-90-574240-1 (Black) 1-90-574200-14 (Majolica Brown) 1-90-574220-14 (Majolica Brown) 1-90-574240-14 (Majolica Brown) 27 28 Part number list on following page. 08/14 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 30: Service Parts

    1-00-574345 Label, Large Caution 3-90-00247 Black Paint 4-00-574319P Cast Top Majolica Brown 1-10-574319-14 Black Paint 4-00-574321P Cast Wing Left Majolica Brown 1-10-574321-14 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 31 Spring Latches with hardware Set of 2 1-00-00927 Burn Pot Gasket Pkg of 5 1-00-07381 Combustion Blower 3-21-08639 Distribution Blower Qty 2 req 3-21-33647 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 32 Touch Up Paint. Black 12 oz Can 3-42-19905 Touch Up Paint Majolica Brown 1-00-0014 Wiring Harness 3-20-08727 DK blue pigtail 3-20-574122 Sky blue pigtail 3-20-574123 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 33 3-44-677160-10 Feeder Air Crossover Kit 1-00-67900 8.14 9MM Silicone Tube 5 Ft 1-00-511427 8.15 Pellet Air Intake Assembly 1-10-06810A Gasket Feeder Air Intake Pkg of 6 3-44-72224-6 8.16 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...
  • Page 34: Contact Information

    Printed in U.S.A. - Copyright 2013 Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/14 3-90-00574c...

This manual is also suitable for:

Accentra 52i pellet insert

Table of Contents