Reference
Information
This section provides mounting and firmware updating information. Topics in this section
include:

Mounting

The FOX T USW 103 can be placed on a tabletop or mounted in a rack or underneath a desk.

Tabletop Use

Attach the provided rubber feet to the bottom four corners of the enclosure.

Mounting Kits

Mount the unit using any optional compatible mounting kit listed on the Extron website
(www.extron.com), in accordance with the directions included with the kit. For
rack-mounting, see
UL guidelines for rack-mounted devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
FOX T USW 103 in a rack.
1.
2.
3.
4.
5.
Mounting
Updating Firmware
UL guidelines for rack-mounted devices
Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient temperature. Therefore, install the FOX T USW 103 in an environment
compatible with the maximum ambient temperature
(Tma = +122 ˚F, +50 ˚C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is no compromised.
Mechanical loading — Mount the equipment in the rack so that a hazardous condition
is not achieved due to uneven mechanical loading.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have an overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (e.g. use of power strips).
FOX T USW 103 Universal Switcher • Reference Information