Rear View Of The Server - Lenovo ThinkServer TD340 User Manual And Hardware Maintenance Manual

70b4, 70b5, 70b6, 70b7
Table of Contents

Advertisement

LED
3
System fan error LED
4
Ambient temperature
limit LED
5
Power supply error
LED

Rear view of the server

This topic provides information to help you locate the connectors and components on the rear of your server.
Status
Solid off
The system fans are operating
correctly.
Solid on (amber)
One or more system fans are
running at low speed or have
been removed.
The server is running at a normal
Solid off
temperature.
Solid on (amber)
The ambient temperature is below
7°C (44.6°F) or over 40°C (104°F).
Solid off
The power supply is working
correctly.
Solid on (amber)
The power supply is likely to fail
or has failed.
Description
Check the BMC for errors and
run the diagnostic programs. See
"Using a diagnostic program" on
page 203.
Note: To identify the failing
system fans, check the status
LEDs on the system board. See
"System board LEDs" on page
56.
Check the BMC for errors and
run the diagnostic programs. See
"Using a diagnostic program" on
page 203.
Check the BMC for errors and
run the diagnostic programs. See
"Using a diagnostic program" on
page 203.
Note: To identify the failing power
supply, check the status LED
near the power cord connector
on the redundant power supply.
Action
.
Chapter 3
Product overview
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents