Running A Consistency Check - Lenovo ThinkServer TD340 User Manual And Hardware Maintenance Manual

70b4, 70b5, 70b6, 70b7
Table of Contents

Advertisement

detailed information about disk rebuild, refer to "Introduction to RAID" in the MegaRAID SAS Software User
Guide on the documentation DVD that comes with your server.
To rebuild a physical drive using the LSI Software RAID Configuration Utility program when a physical drive
in a RAID array fails, do the following:
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 74.
2. On the main interface of the program, select Rebuild and follow the instructions on the screen.
Note: Run a consistency check immediately after the rebuild completes to ensure data integrity for the virtual
drives. See "Running a consistency check" on page 78.
The rebuild rate is the percentage of the computing cycles dedicated to rebuilding failing drives. The rebuild
rate can be configured between 0 percent and 100 percent. At 0 percent, the rebuild operation is done only if
the system is not doing anything else. At 100 percent, the rebuild operation has a higher priority than any
other system activity.
To configure the rebuild rate using the LSI Software RAID Configuration Utility program, do the following:
Note: Using a rebuild rate of 0 or 100 percent is not recommended. The default value is 30 percent.
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 74.
2. On the main interface of the program, select Objects ➙ Adapter ➙ Rebuild Rate.
3. Set the rebuild rate by typing a desired value from the keyboard directly.

Running a consistency check

This topic provides instructions on how to run a consistency check for virtual drives using the LSI Software
RAID Configuration Utility program.
The consistency check operation verifies that all stripes on a virtual drive with a redundant RAID level (RAID
1, RAID 5, and RAID 10) are consistent and the date on the virtual drive is correct. For example, in a system
with parity, checking consistency means computing the data on one drive and comparing the results to
the contents of the parity drive.
You should run a consistency check on fault-tolerant virtual drives periodically. It is recommended that you
run a consistency check at least once a month. You must run a consistency check if you suspect that the
virtual drive data might be corrupted. Ensure that you back up the data before running a consistency check
if you suspect that the data might be corrupted.
To run a consistency check using the LSI Software RAID Configuration Utility program, do the following:
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 74.
2. On the main interface of the program, select Check Consistency and follow the instructions on the
screen.
The consistency check rate is the rate at which consistency check operations are run on a system. The
consistency check rate can be configured between 0 percent and 100 percent. At 0 percent, the consistency
check is done only if the system is not doing anything else. At 100 percent, the consistency check has a
higher priority than any other system activity.
To configure the consistency check rate using the LSI Software RAID Configuration Utility program, do
the following:
78
ThinkServer TD340 User Guide and Hardware Maintenance Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents