HP EliteOne 800 G1 Maintenance & Service Manual page 101

All-in-one
Hide thumbs Also See for EliteOne 800 G1:
Table of Contents

Advertisement

3.
Select Advanced, select Device Options, select LVDS Panel Select, and then select the
manufacturer for the new display panel.
4.
Save your settings, exit F10 Setup, and allow the computer to continue to the operating system.
When you change the LVDS setting to the installed panel type, the BIOS reprograms the EDID with the
correct data. You must set the panel before the Auto-select setting functions correctly.
Updating SMBIOS Information
When replacing the system board, you must reprogram the SMBIOS information on the affected
computer. Failure to reprogram the board will result in eventual failure, such as an activation failure
(need to reactivate the system) or a system recovery failure.
To update SMBIOS information in Computer Setup:
1.
Turn on or restart the computer.
2.
Press
Esc
while the "Press the ESC key for Startup Menu" message is displayed at the bottom of
the screen.
NOTE:
If you do not press
press
Esc
when the monitor light turns green to access the utility.
3.
Press
F10
to enter Computer Setup.
4.
Go to Security > System ID's.
5.
If necessary, press
6.
Edit the fields listed. If the feature byte has data or is not editable, then it was not cleared and
cannot be edited.
System ID Setup Page
Setup Field Name
Product Name
Enter the Model name/number or marketing name.
Serial Number
Enter the Serial Number of Unit.
SKU Number
Enter the SKU or Product Number including Localization Code.
Asset Tag
Enter the 18-byte identifier assigned to the computer.
Feature Byte
Enter the Feature Byte string. The feature byte string is case sensitive.
The label includes spaces after every four characters. You can enter or ignore
these spaces – their only purpose is to help with data entry. There is a
character limitation of 40 bytes per line. When you reach this limit, go to the
next line to continue data entry. BIOS ignores the spaces and lines.
If you make an error during data entry, the data will not validate, and the
computer asks you to correct your data input.
Build ID
The Build ID of the unit.
Esc
at the appropriate time, you must restart the computer and again
Ctrl+A
to initiate edit mode.
Comment
Label
Flexbuild
Support
Support
Support
Flexbuild
Flexbuild
System board
91

Hide quick links:

Advertisement

Table of Contents