Magnum 6KQ Managed Field Switch Installation and User Guide
For DC power input data, see Appendix B. For Dual Source, see Appendix C
.
The rugged metal case of the Magnum 6KQ will normally protect it from
accidental damage in a lab or workplace setting. Maintain an open view of the front to
visually monitor the status LEDs. Keep an open area around the unit so that cooling can
occur from convection while the unit is in operation. The 6KQ has no fans, so it is silent
when in operation. Internal electronics use the case as a heat sink, so the unit may
normally be quite warm to the touch.
3.2

Connecting Ethernet Media

The Magnum 6KQ Switches are specifically designed to support all standard
Ethernet media types within a single Switch unit. This is accomplished by using a family
of different Port Modules which can be individually selected and configured per-slot.
See Section 2.2 for a description of the PMs.
The various media types supported along with the corresponding IEEE 802.3,
802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:
IEEE Standard
Fiber:
100BASE-FX
100BASE-FX
small form factor
small form factor
Copper:
10BASE-T and 100BASE-TX twisted pair100m (328 ft)
1000BASE-TX twisted pair
3.2.1

Connecting Fiber Optic ST-type, "twist-lock"

The following procedure applies to installations using a PM with ST-type fiber
connectors. This procedure applies to ports using a 6KQ module, MST-type port.
1.
Before connecting the fiber optic cable, remove the protective dust caps from
the tips of the connectors on the PM. Save these dust caps for future use.
www GarrettCom com
.
.
Media Type
Max. Distance
1
m
m
Fiber
220m ( ft)
2
sgl.m
Fiber
5Km
1
m
m
Fiber
2.0km (6,562 ft)
2
sgl.m
Fiber
18.0km (95K ft)
1
m
m
Fiber
2.0km (6,562 ft)
1
sgl.
m
Fiber
15 km
100m (328 ft)
1
mm = multi-mode
20
(04/07)
Port Module
GBIC-SXSC
GBIC-LXSC
6K4-MSC, -MST
SSC, SSCL
6KQ-MTRJ, -MLC
6KP4V- SLC
6KQ-RJ45
GBIC-TP
2
sgl.m = single-mode

Hide quick links:

Advertisement

Table of Contents
loading