GarrettCom Magnum 6KQ Hardware Installation And User's Manual page 8

Managed field switch
Hide thumbs Also See for Magnum 6KQ:
Table of Contents

Advertisement

Magnum 6KQ Managed Field Switch Installation and User Guide
1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m
1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km
Fiber Multi-mode connector types supported:
Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL
Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX
Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX
Fiber Port, ST-type (twist-lock): Fiber optic m.-mode, 100BASE-FX
Fiber Port, 1000BASE-FX, SFP modules
Fiber Single-mode connector types:
Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX
Fiber Port, LC-type
Fiber Port, 1000BASE-FX, SFP modules
LEDs: Per Port (one set at the port, one set on swivel top on right side)
LK: Steady ON when media link is operational
ACT: ON with receiver port activity
FDX/HDX: ON = Full-Duplex Mode
100/10: ON = 100Mbps speed
OFF = 10 Mbps
Operating Environment
Ambient Temperature:
-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating
-60° to 195° F (-50° to 85°C) for IEC 60068 Type Test short term rating
Storage Temperature: -60°to 210°F (-50°to 100°C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) option: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable
Packaging
Enclosure: High strength extruded aluminum
Dimensions: 6.85 in. H x 7.5 in. W x 2.0 in. D
Cooling method: Convection, fully-enclosed ribbed-surface aluminum case
used as a sink, designed for vertical mounting, no fans
Weight: 3 lbs. (1.3 kg)
Management Console connector
Serial RJ-45, see details at sec. 3.7
DC Power Supply (Internal, floating ground design)
24VDC Power Input nominal (18 to 36VDC range)
-48VDC Power Input nominal (36 to 60 VDC range)
125VDC Power Input nominal (88 to 150VDC range)
Std. Terminal Block : " -, GND, + "
Power Consumption:
35 watts typical (for a fully loaded fiber model)
www GarrettCom com
.
.
Fiber SFF single-mode, 100BASE-FX
OFF = Half-Duplex Mode
17.4 cm H x 19.1 cm W x 5.08 cm D