Sense Data Management - HP C737990900 Technical Reference Manual

Ultrium drives generation 2 scsi and fc drives volume 3: the scsi interface
Table of Contents

Advertisement

1
C/D
Command Data. Only valid if the SKSV flag is set.
0
1
BPV
Bit Pointer Valid
0
1
Identifies the bit position of the field in error, whether it is a command descriptor or a
Bit Pointer
command parameter list field. When a multi-bit field is in error, this will point to the most
significant bit of that field. Only valid when the SKSV flag is set.
If SKSV =
Field Pointer
/Drive Error Code
descriptor or parameter list an error was detected.
Note that the drive scans from byte 0 bit 7 of a command or parameter list through to byte n
bit 0. The field and bit pointers are set to point to the most significant bit of the field that is in
error. See the illegal field check and the parameter list check.
If SKSV =
The bottom byte contains the drive error code associated with the failure of the previous
command, or zero in the case of no failure and no appropriate error code. If the drive's
power-on self-test failed then, in the absence of an error code associated with the most recent
command, this byte will be set to the error code generated by the failing test.
Note:
Drive error codes are provided for information only; they are intended to assist in product
integration and fault diagnosis. The codes should not be relied on by "generic" host drivers,
since these are specific to the product. For a list of codes, see
Integration Guide, Volume 1 of the HP Ultrium Technical Reference Manual
0
CLN
1

Sense Data Management

The Sense Key Specific Bytes are valid. This will only happen when the bytes assume
the role of Field Pointer Bytes as defined by ANSI. This occurs when an Illegal Field
check detects an error in a command descriptor block or a Parameter List check
detects an error in a command parameter list.
The Field Pointer information applies to the parameter list for the command.
The Field Pointer information applies to the command descriptor block.
The Bit Pointer field is invalid.
The Bit Pointer field is valid. If the SKSV bit is set then the BPV bit must be set as well.
1, this field represents the Field Pointer, identifying in which byte of the command
0, this field represents the Drive Error Code. The top byte of this field will be zero.
The drive is OK.
The drive requires cleaning. The front panel LEDs will be displaying a "clean me"
sequence or message. This bit is cleared to zero after a cleaning cartridge has been
used.
The drive maintains three sets of sense data for every initiator on the bus. For a
single host the following sense data is maintained:
Current sense
U
sense
NIT ATTENTION
Chapter 10 of the Hardware
.
Commands 131

Advertisement

Table of Contents
loading

Table of Contents