HP C737990900 Technical Reference Manual page 61

Ultrium drives generation 2 scsi and fc drives volume 3: the scsi interface
Table of Contents

Advertisement

0
The Save Page (SP) flag is not supported and must be set to 0.
SP
The Page Control field defines the type of parameter values to be selected:
PC
00b
No operation is performed. The Parameter List Length must be zero. If it is not, check
or
condition invalid field in CDB is set.
10b
01b The drive will clear logs as specified by the parameter data.
11b The drive will clear all of its internal logs.
Parameter
0
No data is to be transferred. This is not considered an error.
List Length
>0 Specifies how many bytes of parameter data are to be sent. The data transferred will
consist of zero or more 4-byte log page headers with the page length in those headers
set to zero. For each log page header received, the drive clears the associated log.
Commands
61