A reserved field should always be set to zero. The drive checks reserved fields, and if one is
Reserved
non-zero then it will reject the command with
Multi-Byte
A multi-byte parameter field in a command is "big-endian", that is, bit 7 of the first byte of this
field is the most significant.
Parameter
The control field is mainly concerned with the use of linked commands. These are not supported
Control
by the LTO SCSI Command Set, so a
anything other than zero.
This field is ignored by the firmware
Vendor-Unique
0 The Normal ACA flag is 0, indicating that it is not supported.
NACA
0
Flag
Link
0 Linked commands are not supported.
CHECK CONDITION
will be generated if this field is set to
CHECK CONDITION
Commands—Introduction
.
39