HP C737990900 Technical Reference Manual page 47

Ultrium drives generation 2 scsi and fc drives volume 3: the scsi interface
Table of Contents

Advertisement

000b
Peripheral Qualifier
011b
Peripheral Device
01h
Type
08h
1Fh
RMB
1
Device-Type Modifier
0
Version Number
3
0
AERC
NACA
0
HiSup
0
Response Data
2
Format
Additional Length
The length in bytes of the length of the rest of the Inquiry data.
5Bh There are 91 (5Bh) more bytes of Inquiry data.
BQue
Basic Queuing flag
0
1
EncSvr
The Enclosure Services flag is zero to indicate that the tape drive does not support
Enclosure Services command.
MultiP
0
1
MChngr
The Medium Changer bit:
0
1
Adr16
The 16-Bit Address flag is set according to whether the hardware supports this bus
feature. The flag is only valid for parallel SCSI and is clear for all other low level
interfaces.
RelAdr
0
Inquiry Data Fields
There is a device on the logical unit selected, so the LUN field in the identify
message was 0.
The LUN field in the identify message has specified an unsupported logical unit.
This means any LUN other than 0.
Sequential Access Device
Medium Changer Device
No Device (the Peripheral Qualifier will be 011b in this case)
The Removable Medium bit is one, indicating that the tape can be removed.
This is a six-bit user defined code, set to zero.
The Version Number is always set to 3, indicating that the drive complies to
ANSI X3.301:1997
This field is zero, indicating that Asynchronous Event Reporting Capability is not
supported.
The Normal ACA flag is 0, indicating that it is not supported.
The Hierarchical Support flag is 0, indicating that the hierarchical addressing
model is not supported.
This field has the value 2, indicating that the Inquiry Data format complies with the
ANSI version of SCSI-2.
The flag is zero for SCSI drives. Together with the CmdQue flag being zero this
indicates that the device does not support tagged tasks for this logical unit.
The flag is 1 for Fibre Channel drive, indicating the basic queuing is supported.
The drive has a single port and does not implement multi-port requirements.
The drives has multiple ports.
The drive is not embedded within or attached to a medium transport element.
The drive is embedded within or attached to a medium transport element.
Relative Addressing is not supported.
Commands