4.3 Rear Panel Connectors

Refer to Fig.4-2 and Table 4-2 for description of the Rear Panel connectors.
No.
Connection
1
AC Input Connector
2
DC output
Analog Control and
3
signals. J1
Local/Remote sense
4
connector J2
Isolated control and
5
signal. J3
Remote Serial Out
6
connector
Remote Serial In
7
connector
8
USB Connector
LAN Connector
9
(optional)
10
Ground screw
11
Optional Interface
Table 4-2: Rear panels connections
Fig. 4-2: Rear panel connections
Description
IEC320-16 TYPE CONNECTOR
Plug for DC output.
Connector for remote analog interface. Analog control and monitoring.
Referenced internally to output potential -S.
Connector for making remote sensing connections to the load for
regulation of the load voltage and compensation of load wire drop.
Control and monitoring signal, isolated from the output potential.
RJ-45 type connector, used for chaining power supplies to/from a serial
communication bus.
RJ-45 type connector, use for connecting power supplies to RS232 or
RS485 port of computer for remote control purposes. When using several
power supplies in a power system, the first unit Remote-In is connected
to the computer and the remaining units are chained, Remote-In to
Remote-Out.
USB interface connector, type B
LAN interface connector, type RJ-45
M4X8 for chassis Ground connection
Position for GPIB Interface (shown) or Isolated Analog Interface IS510/IS420.