Plumbing

The machine should be connected to two
water supply valves, which conform with
local and national regulations. Installation
must be carried out by an authorized
service technician.
To ensure the machine is correctly
connected please follow the installation plan
and the separate installation instructions
supplied with the machine.
Installation Instructions
Connecting the water intake / water
drain hoses
See the enclosed installation plan.
A water pressure flow rate of at least 14.5 psi,
maximum 145 psi is required.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
The hoses should only be replaced with
genuine Miele spare parts which fulfill the
pressure requirements.
The hot water intake must not exceed a
temperature of 158°F (70°C).
Cold water connection only
See the enclosed installation diagram.
,
Must comply with all local codes.