Non-Ip Redundancy Configuration; Figure 3-3. Cdm-570L Cli 1:1 Redundancy Configuration Screen - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Modem and Switch Configuration
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-3. CDM-570L CLI 1:1 Redundancy Configuration screen

 
All configuration changes can only be made to the Online Modem and will require 
the  user  to  "Save Parameters to permanent storage"  to  ensure  the 
configuration change is also applied to the Backup Modem.
3.5.2

Non-IP Redundancy Configuration

Setup  of  the  CDM‐570L  modems  for  1:1  Redundancy,  when  the  terrestrial  data  type  is  non‐
Ethernet (i.e. RS422, G.703), is as follows: 
 
Step
Procedure
On both modems, Enable 1:1 Redundancy:
1
Redundancy Configuration
Connect all cables – including the control cable, IF cable and data 'Y'cables – to the modems
2
and the CRS-170A.
 
1:1 Redundancy set to ENABLE.