Figure 1-7. Cdm-625/750/700/710/710G 1:1 Ip Redundancy Managed Switch Mode - Switchover - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Introduction
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1-7. CDM-625/750/700/710/710G 1:1 IP Redundancy Managed Switch Mode – Switchover
 
As shown in Figure 1‐7, in the event of a fault occurring on the Online Modem 'A', the following 
will occur: 
 
Modem 'A' goes Offline and disables its Ethernet data interface. 
 
Simultaneously, Modem 'B' goes Online and enables its Ethernet data interface. 
 
Layer 2 Switch 'A' senses that Port 4 is no longer active and clears the CAM table entries 
for that port. 
 
When the next Ethernet packet from Local PC 'A' destined for Remote PC 'B' arrives at 
Switch 'A', there is no CAM entry for the PC 'B' MAC, so it will be broadcast to all active 
ports. 
 
When  the  next  Ethernet  packet  from  Remote  PC  'B'  arrives  at  Switch  'A',  Switch  'A' 
dynamically adds the PC 'B' MAC to the CAM table for Port 3. 
 
CDM-625/750/700/710/710G
CDM-625/750//700/710/710G
CDM-625/750/700/710/710G/
1–11
Revision 9
MN/CRS170A.IOM

Advertisement

Table of Contents
loading

Table of Contents