Cabling The Cdm-600L (Clm-9600L) - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Cables and Connections
4.8

Cabling the CDM-600L (CLM-9600L)

Comtech  EF  Data  CLM‐9600L  Open  Network  Satellite  Modem  Installation  and 
 
Operation Manual (CEFD P/N MN/CLM9600L.IOM) 
Comtech  EF  Data  CRS‐150    1:1  Redundancy  Switch  Installation  and  Operation 
Manual (CEFD P/N MN/CRS150.IOM) 
Appendix A. CABLE DRAWINGS 
 
The  block  diagram shown in Figure 4‐48 depicts  connection of a  pair of  CDM‐600L  (CLM‐9600L) 
Open Network Satellite Modems together with the CRS‐150 and CRS‐170A switches. 
 
Cable  assemblies  that  may  be  supplied  with  the  CRS‐170A  when  used  with  the  CDM‐600L 
(CLM‐9600L) and CRS‐150 are listed in the table included in Figure 4‐48. 
 
When connecting the Control cable between the CRS‐170A and the modems, ensure 
that screw locks on the 'D' type connectors are securely fastened. This will prevent 
the  accidental  unmating  of  the  cable,  particularly  when  a  standby  unit  is  being 
removed or replaced. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CEFD Part No.
CA/WR10456-4
CA/RF10453-4
 
Figure 4-48. CDM-600L (CLM-9600L) Block Diagram: Cable Connections
Qty
Description
2
Cable – 1:1 Y-Splitter, Data/Control, DB-25M
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type 'N', 4'
4–57
Revision 9
MN/CRS170A.IOM
DB-25M, 4' / DB-9M, 1'

Advertisement

Table of Contents
loading