1.2.1 Operation With Cdm-625 / 840 / 750 / 570L / 700 / 710 / 710G Modems - Comtech EF Data CRS-170A Installation And Operation Manual

L-band 1:1 redundancy switch
Table of Contents

Advertisement

CRS-170A L-Band 1:1 Redundancy Switch
Introduction

1.2.1 Operation with CDM-625 / 840 / 750 / 570L / 700 / 710 / 710G Modems

The  CRS‐170A  is  configured  with  two  modems  to  form  a  complete  1:1  redundant  modem 
system. Within the CRS‐170A, a redundancy controller continually monitors the status of faults 
for both modems to determine which modem should be Online and Offline. The control cables 
between the modems and the CRS‐170A include four signal groups: 
 
First,  serial  full‐duplex  communication  lines  are  routed  from  one  modem  to  the  other 
modem  via  the  CRS‐170A.  Using  these  lines,  this  Online  modem  can  interrogate  the 
Offline  modem  at  regular  intervals  to  determine  its  configuration.  If  a  difference  in 
configuration is detected, the Online modem will reconfigure the Offline modem so that 
the  configurations  are  always  synchronized.  This  process  is  entirely  automatic  –  if  the 
Offline modem is replaced, it does not have to be manually reprogrammed to match the 
Online modem. 
 
Second,  the  Unit,  Tx  and  Rx  faults  signals  from  both  modems  are  routed  to  the 
CRS‐170A.  This  allows  the  redundancy  controller  to  always  know  the  health  status  of 
both modems. 
 
Third,  the  online/offline  signals  are  routed  from  the  CRS‐170A  to  each  modem.  Based 
on the modem faults, the CRS‐170A will determine which modem should be Online and 
Offline.  In  the  event  that  both  modems  indicate  faults  through  some  malfunction,  the 
CRS‐170A switch will select, by default, Modem A. 
 
Fourth, +12V is routed from each modem to the CRS‐170A for operational power. This 
power  from  both  modems  is  diode  OR'd  so  that  the  switch  remains  active  if  power  is 
lost from one of the modems. 
 
Mode Switches – The Mode DIP switches, located on the antenna side of the CRS‐170A, allow 
the  switch  to  operate  in  two  different  modes:  Normal  (Intelligent  Controller)  Mode  and 
SDM‐300L/CDM‐600L (Dumb Controller) Mode. 
 
Use Normal (Intelligent Controller) Mode for CDM‐625, CDM‐840, 
CDM‐750,  CDM‐570L,  CDM‐700,  CDM‐710  and  CDM‐710G 
modems. 
 
Use SDM‐300L/CDM‐600L (Dumb Controller) Mode for SDM‐300L 
and CDM‐600L (CLM‐9600L) modems. 
 
IF  Switching  –  The  CRS‐170A  provides  L‐Band  redundancy,  but  when  switching  occurs,  it 
accommodates more than just the L‐Band signals: 
 
On the Tx side, it switches the Tx L‐Band signal, the 10 MHz reference to the BUC, DC 
power to the BUC and, on CDM‐570L modems, FSK signaling to the BUC. 
 
On the Rx side, it switches the 10 MHz reference to the LNB, and DC power to the LNB. 
The Rx L‐Band signal from the LNB is split in a power divider to continuously drive both 
1–5
Revision 9
MN/CRS170A.IOM

Advertisement

Table of Contents
loading

Table of Contents