3.1

Overview

In  order  to  avoid  damage  to the  modems  and  CRS‐170A  switch,  it  is  important  to 
follow this sequence of configuration: 
 
First,
 configure the modems for 1:1 redundant operation as outlined in this 
chapter in Sect. 3.2 through Sect. 3.7. 
Second,
 once the modems have been properly configured for 1:1 redundant 
operations,  set  the  DIP  switches  on  the  CRS‐170A  to the  correct modem 
selection,  as  outlined  in  this  chapter  in  Sect.  3.8  CRS‐170A  Switch  DIP 
Settings.
Third,
  once  the  modem  and  switches  have  been  properly  configured, 
connect  the  cables  between  the  powered  OFF  modems  and  switch  as 
outlined in Chapter 4. CABLES AND CONNECTIONS.