CRS-170A L-Band 1:1 Redundancy Switch
Modem and Switch Configuration
Figure 3-3. CDM-570L CLI 1:1 Redundancy Configuration screen
All configuration changes can only be made to the Online Modem and will require
you to "Save Parameters to permanent storage" to ensure the
configuration change is also applied to the Backup Modem.
3.5.2

Non-IP Redundancy Configuration

Setup of the CDM-570L modems for 1:1 Redundancy, when the terrestrial data type is non-
Ethernet (i.e. RS422, G.703), is as follows:
Step
Procedure
On both modems, Enable 1:1 Redundancy:
1
Redundancy Configuration  1:1 Redundancy set to ENABLE.
Connect all cables – including the control cable, IF cable and data 'Y'cables – to the modems
2
and the CRS-170A.