Cabling To The Cdm-600L (Clm-9600L); Figure 4-14. Cdm-600L (Clm-9600L) Block Diagram: Cable Connections - Comtech EF Data CRS-150 Installation And Operation Manual

1:1 redundancy switch
Table of Contents

Advertisement

CRS-150 1:1 Redundancy Switch
Cables and Connections
4.3

Cabling to the CDM-600L (CLM-9600L)

The block diagram shown in Figure 4-14 depicts connection of a pair of CDM-600L (CLM-9600L)
modems together with the CRS-150 and CRS-170A switches.

Figure 4-14. CDM-600L (CLM-9600L) Block Diagram: Cable Connections

The following table lists cable assemblies that may be supplied with the CRS-170A when used
with the CDM-600L (CLM-9600L) and CRS-150. Other cables between the CRS-150 and the
CDM-600L (CLM-9600L) modems are supplied with the CRS-150.
QTY
Part No.
2
CA/WR10456-4
4
CA/RF10453-4
When connecting the Control cable between the CRS-150 and the modems,
ensure that screw locks on the 'D' type connectors are securely fastened. This
will prevent the accidental un-mating of the cable, particularly when a standby
unit is being removed or replaced.
Cable – 1:1 Y-Splitter, Data/Control, DB-25M
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type 'N', 4'
4–16
Description
DB-25M, 4' / DB-9M, 1'
Revision 2
MN/CRS150.IOM

Advertisement

Table of Contents
loading