Installing The Fan Controller Board; Backplane/Fan Bay Cage; Removing The Backplane/Fan Bay Cage - Dell Power Supply C8000 Owner's Manual

Table of Contents

Advertisement

Installing the Fan Controller Board

CAUTION:
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized is not covered by
warranty. Read and follow the safety instructions that came with the product.
NOTE:
If you are installing a new fan controller board, prior to upgrading your
system, download and install the latest fan controller board firmware version from
dell.com/support. Follow the instructions included in the file download to install the
update on your system.
1 Place the fan controller board into the fan controller bay. See Figure 3-16.
2 Replace the four screws securing the fan controller board to its tray. See
Figure 3-16.
3 Insert the fan controller board assembly into its enclosure bay.
4 Secure the fan controller board assembly to the enclosure with the two
thumbscrews. See Figure 3-16.

Backplane/Fan Bay Cage

Removing the Backplane/Fan Bay Cage

CAUTION:
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized is not covered by
warranty. Read and follow the safety instructions that came with the product.
1 Disconnect the server enclosure from the electrical outlet or PDU.
2 Remove the fan controller board. See "Removing the Fan Controller
Board" on page 211.
212
Installing System Components
Many repairs may only be done by a certified service technician. You
Many repairs may only be done by a certified service technician. You