C3.0
DUAL-SOURCE OPTION, THEORY OF OPERATION
The Dual-Source DC power option is designed using diodes inside of the
switch on each DC power input line. A
diode is placed in each of the f
lines (behind the four external pow
conne
ctio
n terminals) so that power
from an external source can only flow
into the switch. This allows the switch
to operate wh
enever DC power is
correctly applied to either or both of the two inputs
C4.0
FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN
a)
The switch can receive power from either input, "A" or " ". The switch will norm
pow
er from the DC source with the highest voltage at a given time.
h
b)
The
switc
will not allow power to flow from a higher voltage input to a lower voltage inpu
i.e.
the two DC power sources are not mixed together by the switc
c)
When one correct DC input is present, the switch will receive power if the other DC input is
absent, or even if it is connected with reverse polarity or shorted or grounded.
d
)
Reverse polarity connections, if they should accidentally
the
switch or power supply internally (nor will it blow the fuse in the internal power supply
bec
ause of the blocking action of the diodes. This is true even if one input connection is
rev
ersed while the switch is operating from the other source.
e
)
The
switch will not receive power (and will not work) when both inputs are simultaneously
absent or are both incorrectly connected.
C5.0
INSTALLATION
This section describes the proper connection of the -48VDC, 24, 100 and
125VDC dual source leads to the DC power terminal block on the Magnum Quad-Series
Switch (shown in Figure C4.0 with 48v input as example).
T
he –48VDC terminal block on the Magnum Quad-Series Switch is located on
the right
rear of the unit and is equipped with five (5) screw-down lead posts (see Fig
C5.0). The primary terminals are identified as positive (A+), negative (A-), and the
secondary power terminals as negative (B-), positive (B+). The chassis "earth" or ground
(GND), is a threaded post with a #6 nut. The dual source terminal block for 24, 100
and 125VDC are similar.
Figure C5.0: DC Dual Source, wiring connection to the external Termin
on a Magnum QS5116 48VDC wih Dual-Source option
www GarrettCom com
.
.
our
input
er
A+ A- B- B+
36-70VDC
36-70VDC
GND
48
Installation and User Guide (06/03)
uration with Dual-Source Option units.
A+
A-
B-
B+
GND
.
B
h.
oc
cur on either inpu wil
HUB
SUPPLY
+
FUSE
-
CHASSIS
GND
ally dr
aw its
t,
t,
l not d
amage
)
ure
al Block