GarrettCom Magnum ITS Blade Installation And User Manual

GarrettCom Magnum ITS Blade Installation And User Manual

Ethernet switch for 2070 traffic controller chassis

Advertisement

Quick Links

Magnum ITS Blade
Ethernet Switch for
2070 Traffic Controller Chassis
Installation and User Guide
www GarrettCom com
.
.

Advertisement

Table of Contents
loading

Summary of Contents for GarrettCom Magnum ITS Blade

  • Page 1 Magnum ITS Blade Ethernet Switch for 2070 Traffic Controller Chassis Installation and User Guide www GarrettCom com...
  • Page 2 Controllers contain no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum ITS Blade Ethernet “2070” Switch products, consult Section 5, Troubleshooting, of this User Guide. Copyright © 2003 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 3 Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 4 ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are heavy duty, feature fiber-built-in ports, and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications.
  • Page 5: Table Of Contents

    Frame Buffering and Latency............... 7 Features and Benefits ................9 Applications ..................10 INSTALLATION ................. 11 Locating Magnum ITS Blade, 10/100Mb Hardened Switch....11 Connecting Ethernet Media..............11 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5,)....11 3.2.2 Connecting Fiber Optic SC-type, "Snap-In"...
  • Page 6: Specifications

    Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) SPECIFICATIONS Technical Specifications Ports Performance Fiber, ports #1 and # 8, full duplex at 100Mbps Copper (RJ-45) ports 2-7: auto-negotiating 10/100 Mbps, MDI / MDIX auto-crossover is automatically handled Network Standards IEEE 802.1p QoS prioritization, 802.3u, 802.3x flow control...
  • Page 7 Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) Model 2070 Chassis Standards Fits into slot A1 or A2, draws power from the Model 2070 chassis power supply. Note- the ITS Blade is stand-alone for Ethernet operations; it...
  • Page 8: Ordering Information

    TC62F DC jack plug. Magnum ITS models with other fiber connector types and combinations available, request quote for additional information. GarrettCom, Inc. reserves the right to change specifications, performance characteristics and / or model offerings without notice. www GarrettCom com...
  • Page 9: Introduction

    Installation and User Guide (this manual) Product Registration Card Remove the Magnum ITS Blade from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. To validate the product warranty, please complete and return the enclosed Product Registration Card to GarrettCom, Inc.
  • Page 10 SC-type fiber connectors. Designed specifically to operate in Model 2070 Traffic chassis in temperature uncontrolled road side boxes, the Magnum ITS Blade can easily sustain the heat…. and the cold. Armored with unique thermal techniques (patent pending) developed by GarrettCom...
  • Page 11: 100Mb Fiber Ports, Sc Connectors

    EMI noise immunity. 100Mb Fiber ports, SC Connectors The Fast Ethernet fiber switched ports on the Magnum ITS Blade operate at fixed 100Mb speed and full-duplex mode for the best performance. The ITS Blade’s fiber ports are factory- built as either a multi-mode or single-mode SC connectors.
  • Page 12 This dynamic buffer allocation provides the capability for the maximum resources of the Magnum ITS Blade to be applied to all traffic loads, even when the traffic activity is unbalanced across the ports. Since the traffic on an operating network is constantly varying in packet...
  • Page 13: Features And Benefits

    Features and Benefits 100Mb switching services for high performance Ethernet LANs Magnum ITS Blade provides Fast Ethernet switching on all ports. They perform high-speed filter/forward operations on the traffic, giving each port’s segment a full 100Mb (or possibly 10 Mb for RJ-45 ports) of bandwidth.
  • Page 14: Applications

    Some local users (using RJ-45 ports) may operate at 100Mbps, and some users and utility devices may run at 10 Mbps. A Magnum ITS Blade Hardened Switch serves this requirement economically and efficiently. The six full- and half-duplex switched ports make the required setup simple for collection of traffic data, including streaming video from one or more cameras.
  • Page 15: Installation

    This chapter provides instructions for installing Magnum ITS Blade units. Locating Magnum ITS Blade, 10/100Mb Hardened Switch The location of a Magnum ITS Blade Hardened Switch is designed primarily for the specific application, such as road traffic data collection and control stations, the Magnum ITS Blade draws the power from 2070 chassis for high reliability and convenience in out-of-the way locations.
  • Page 16: Connecting Fiber Optic Sc-Type, "Snap-In

    Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used.
  • Page 17: Connecting Fiber Optic St-Type, "Snap-In" (Optional)

    Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) The LINK LED for the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after cable connection, the normal cause is improper cable polarity.
  • Page 18: Connections To Nic's To Support Auto -Negotiation, Rj-45

    Mbps traffic. Powering the Magnum ITS Blade Switches The Magnum ITS Blade is powered up from the A1 or A2 backplane of a standard 2070 Traffic Controller chassis. The ITS Blade will draw about 1.9A from 5VDC at pin 29 of the backplane connector. The PWR led will turn GREEN as soon as the power is applied to the ITS Blade.
  • Page 19: Operation

    Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) Typical Model 2070 Chassis, rear view OPERATION- the function and operation of the Magnum ITS Blade Switches. Dual-Speed Functionality, and Switching The Magnum ITS Blade Hardened Switch provide six 10/100 RJ-45 switched ports, and two 100Mb fiber ports.
  • Page 20: Auto-Negotiation And Speed-Sensing

    Switching, Address Learning The Magnum ITS Blade has address table capacity of 16K node addresses, and are suitable for use in large networks. They are self-learning, so that as nodes are added or removed or moved from one segment to another, the ITS Blade automatically keeps up with node locations.
  • Page 21: Led's

    However, if you are unsure of the procedures described in this section or if the Magnum ITS Blade Hardened Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
  • Page 22: When Calling For Assistance

    Magnum ITS Blade Hardened Switches for 2070’s Installation and User Guide (02/03) If the problem is isolated to a network device other than the Magnum ITS Blade Hardened Switch product, it is recommended that the problem device is replaced with a known good device.
  • Page 23: Return Material Authorization (Rma) Procedure

    (user) charge. Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 24: Appendix A: Warranty Information

    GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.

This manual is also suitable for:

Tc62f-2mscTc62f-1m1sscTc62f-2sscTc62f-nofTc62f-ps-test

Table of Contents