1.8 Adjusting the Scanner Section

1.8.1 Installing glass

(a) Installing ADF glass
To install new ADF glass, wipe off the mounting
surface and mount the glass by placing it at the
position shown right.
(b) Installing original glass
Original glass should be installed in the following
manner:
1. Place the ADF glass by aligning with the posi-
tioning tab.
2. Hold original glass to the stopper and tighten 4
screws.
3. Hold original glass stay to original glass and
tighten 2 screws.
e-STUDIO160/200/250 ADJUSTMENT ITEMS
ADF glass
Tab
Original
glass
Screw
1 - 74
Fig. 1-8-1
Stopper
Fig. 1-8-2
Original glass stay
Original glass
Screw
Fig. 1-8-3