(3) In order to set the distance "D" to 50 mm.
Notes: 1. An increase in the value increases the distance "D" (0.4 mm/step).
2. Adjustment value is able to be input within the range of 0 - 15. Default adjustment value is 8.
In case of the cassette 1 feeding (Code "440"), adjustment value is within the range of 0 - 40
(Default adjustment value is 23).
3. Since the cassette 1 adjustment value becomes a standard for all adjustments, this adjustment
must always be performed in the order stated above.
4. The adjustment is made for each paper cassette. Paper cassette selection values (1) and cor-
responding codes (3) in paper cassette adjustment.
Paper cassette
Cassette 1
Cassette 2
Cassette 3/4
Bypass
LCF
5. To confirm the adjustment of ADU (code 445), do not print a test print in the procedure in (1),
but copy the TEST CHART.
e-STUDIO160/200/250 ADJUSTMENT ITEMS
Cassette selection value
1
2
3/4
0
3
1 - 60
Code
440
441
444
442
443
December 2002 TOSHIBA TEC