SENSOR TEST (04) ITEMS
Data
Bit
Input info.
1 (A1)
7
A/D CH0 b7
6
A/D CH0 b6
ASIC1
5
A/D CH0 b5
A/D
4
A/D CH0 b4
CH0
3
A/D CH0 b3
2
A/D CH0 b2
1
A/D CH0 b1
0
A/D CH0 b0
2 (A2)
7
A/D CH2 b7
6
A/D CH2 b6
ASIC1
5
A/D CH2 b5
A/D
4
A/D CH2 b4
CH2
3
A/D CH2 b3
2
A/D CH2 b2
1
A/D CH2 b1
0
A/D CH2 b0
3 (A3)
7
A/D CH3 b7
6
A/D CH3 b6
ASIC1
5
A/D CH3 b5
A/D
4
A/D CH3 b4
CH3
3
A/D CH3 b3
2
A/D CH3 b2
1
A/D CH3 b1
0
A/D CH3 b0
4 (IO1)
7
MEM2DET
I/O
6
MEM1DET
E0100C
5
SDRAM2ID
4
SDRAM1ID
3
PCLSET
2
AU1SET
1
DRUM
0
FUSE
5 (IO2)
7
6
I/O
5
E01006
4
3
2
1
0
FAXDET
e-STUDIO160/200/250 ADJUSTMENT ITEMS
Fusing thermistor A/D value
The value for temperature data is expressed with 8 bits.
Fusing side thermistor A/D value
The value for temperature data is expressed with 8 bits.
Drum thermistor A/D value
The value for temperature data is expressed with 8 bits.
Option MEM2 connection signal
(PWA-F-MEM Optional memory PWA)
Option MEM1 connection signal
(PWA-F-MEM Optional memory PWA)
Detection signal for MEM PWA2 256 M bit SDRAM
Detection signal for MEM PWA1 256 M bit SDRAM
PCL PWA connection detection signal
I-FAX PWA connection detection signal
Presence or absence detection of process unit
Detection of new or old process unit
-
-
-
-
Reserved
-
Reserved
-
Reserved
-
Reserved
FAX PWA (GD-1061) connection signal
Function
-
-
-
1 - 28
Value
00H-FFH
00H-FFH
00H-FFH
0: Connected
1: Not connected
0: Connected
1: Not connected
0: 256 M bit
1: 64 M bit/128 M bit
0: 256 M bit
1: 64 M bit/128 M bit
0: Connected
1: Not connected
0: Connected
1: Not connected
0: Without 1: With
0: Normal 1: New
-
-
-
-
-
-
-
0: Connected
1: Not connected
December 2002 TOSHIBA TEC