Toshiba e-STUDIO160 Service Handbook page 20

Digital multi function
Table of Contents

Advertisement

Scan image processing parameter 600 DPI
Code
Factor
620
Image
No. of units: HPF table number
quality
0: Use of default value
1: Text/Photo mode
2: Photo mode
3: For Text mode
4 - 9: Unused
No. of tens: Filter combination intensity
0: Use of default value
1 - 9: Filter combination intensity
621
Image
Ditto
quality
622
Image
Ditto
quality
693
Density
Range correction on original set on the
ADF or RADF.
Set whether the value of the background
peak and text peak are fixed or not.
If they are fixed, the range correction is
performed with standard values.
The values of the background peak and
text peak affect the reproduction of the
background density and text density re-
spectively.
The number of units: Data while automatic
density is selected.
The number of tens: Data while manual
density is selected.
Background peak
1: fixed
2: varied
694
3: fixed
695
4: varied
e-STUDIO160/200/250 ADJUSTMENT ITEMS
Adjustment item
Text peak
fixed
fixed
varied
varied
Image
Image
quality
Default
mode
mode
PPC
Text/Photo
1
PPC
Photo
2
PPC
Text
3
PPC
Text/Photo
12
Photo
12
Text
44
1 - 12
Acceptable
value *1
0-99
The larger the intensity
coefficient the stronger the
intensity.
0-99
0-99
11-14
21-24
31-34
41-44
December 2002 TOSHIBA TEC
Refer to
page
1-66
1-66
1-66

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio200E-studio250

Table of Contents