1.10 MAIN PWA replacement procedure

1. Downloading of the MAIN PWA firmware
For details, see chapter 5 of the Service Handbook.
2. Execution of 08-388 mode. (Reading of the total counter value)
0
8
Power ON
3. RAM Clear with the [1], [3], and [*] keys.
1
*
3
Power ON
4. Execution of 08-665 mode (05: adjustment clear/08: programming clear)
0
8
Power ON
5. RAM Clear with the [1], [3], and [#] keys.
1
3
#
Power ON
6. Download the scanner PWA firmware, if necessary, after confirming the version of it.
7. Settings for the country code or region code
0
2
Power ON
8. Settings for the date and time
For details, see chapter 5 of the Operator's Manual.
PROGRAM
INITIAL SETUP
9. Writing in memory (entering the drum counter value (DRUM COUNTER), long size counter value
(A3/LD) and short size counter value (A4/LT)).
For the setting value, refer to the DRUM UNIT LIST printed before replacing the MAIN PWA.
When the DRUM UNIT LIST is not printed, perform the following setting.
Drum counter value:
Long size counter value: Enter "0."
Short size counter value: Enter the remainder obtained by dividing the total counter value (08-351)
For the setting procedures, refer to section 1.2.5 of the Service Handbook.
e-STUDIO160/200/250 ADJUSTMENT ITEMS
SET
3
or
8
8
START
Warming up
Power OFF
SET
6
or
6
5
START
Warming up
Power OFF
Without Fax kit
Setting the country or region code for the
1
LT:
CND .
4
4
A4:
CND:
8 6
With Fax kit
See the 1.2.6 of the Service Handbook (GD-1061).
0
3
0
DATE & TIME
Find a remainder by dividing the total counter value (08-351) by the pro-
cess unit life value (27k or 33k).
Enter the value obtained by multiplying the remainder by 10.
by the process unit life value (27k or 33k).
Power OFF
Power OFF
SETTING
1
DD-MM-YYYY DAY
15-01-2003 WED
1 - 90
SET
or
START
HH:MM
10:10PM
December 2002 TOSHIBA TEC