Sp Mode Settings For Ieee 1394 - Ricoh B064 Service Manual

Ricoh mfp service manual
Hide thumbs Also See for B064:
Table of Contents

Advertisement

SP Mode Settings for IEEE 1394

The following SP commands can be set for IEEE 1394.
To enter the SP mode:
1. Press Clear Modes
2. On the operation panel keypad, press .
3. Hold down Clear/Stop  for more than 3 seconds.
4. Press "Copy SP" on the touch-panel to open the SP command selection
screen.
SP Mode (Service)
Feed
SP1XXX
Drum
SP2XXX
Process
SP3XXX
Scanner
SP4XXX
Mode
SP5XXX
Periphs
SP6XXX
Data Log
SP7XXX
Data Log2
SP8XXX
5. Enter .
SP No.
Name
5839-004
Device Name
5839-007
Cycle Master
5839-008
BCR Mode
5839-009
IRM 1394a Check
5839-010
Unique ID
5839-011
Logout
5839-012
Login
5839-013
Login MAX
SM
Open All
Close All
Copy Window
COPY: SP1-001-001
Group
Page
Line
Line
Page
Group
Sets the names for all the physical devices connected to
the IEEE 1394 firewire network.
Enables or disables cycle master function of the IEEE 1394
standard bus.
Sets the BCR (Broadcast Channel Register) setting for the
Auto Node operation for the standard IEEE1394 bus for
when IRM is not in use. Three settings are available: 00,
01, 11.
Determines whether an IRM check for IEEE 1394 is
conducted for the Auto Node when IRM is not used.
Enables the "Node_Unique_Id" setting for enumeration on
the standard IEEE 1394 bus.
Determines how successive initiator login requests are
handled during login for SBP-2.
Enables or disables exclusive login for SBP-2.
Sets the limit for the number of logins for SBP-2. Range: 1
~ 62.
1-93
MFP OPTIONS: B064 SERIES
14APR 2002 03:25
Exit
X-XXX-XXX
SP Direct
21
Initial
0
Prev Page
Next Page
B064I999.WMF
Function
B064 Series/B140 Series/G126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents