3.8.5 TRANSFER POWER PACK

[A]
[B]
Transfer belt unit (
[A]: Wire ( x 1) (all wire guides)
[B]: Ground terminal wire (wire guide x 1)
• This terminal wire does not disconnect from the power pack.
• Loosen the two left screws of the transfer belt lift solenoid [C], and remove
the top screw [D] to free the ground terminal wire.
[E]: Transfer current terminal wire (wire guides x 2)
[F]: Transfer power pack ( x 1)
• Disconnect the two standoffs on the right edge of the power pack and
remove.
Re-installation
• Confirm that the left edge of the power pack is below the tabs on the left.
• Confirm that the transfer current terminal wire is below the wire guides on the
right.
• Pass the ground terminal wire under the top connector of the solenoid bracket
and tighten all the screws of the solenoid bracket.
• Make sure the wire is below all the wire guides at the top.