Maintenance; Replacing The Hard Drive - Infortrend EonNAS Pro Series Hardware Manual

Table of Contents

Advertisement

WARNING
Replace a failed hard disk drive from the system as soon as possible to ensure data
redundancy.
When inserting a hard drive, do not use excessive force. Forcing the hard drive can
damage the connector pins either on the hard drive itself or the backplane within the
system enclosure.
DO NOT remove two or more hard drive trays out of the enclosure at the same time!
Should you suffer multiple hard drive failures, always replace one hard drive at a time!
User replaceable components:
Hard drive

Replacing the Hard Drive

The easiest way to find out if your hard disk drive has failed is by looking at the
drive status
LED. If the power status lights up red, it indicates that that particular hard
disk drive has failed. Hard drives are hot swappable, to replace it, please refer to the
following procedure:
1. Locate the failed hard drive with a red status LED
2. Unlock the hard drive tray by turning the bezel to the unlock position.
EonNAS Pro Series Hardware Manual

Maintenance

56
(hard drive status
LED).
hard