Problem
Burner will not light
Burner flame is low
Burner flame goes
off
immediately
after ignition
Emitter
unevenly
Thick black smoke
Carbon build-up
Manufacturer: Changzhou Wellife Furnace Co. Ltd.
Xinqiao Village, Zouqu Town, Wujin District, Changzhou City
Jiangsu Province, China
Tel: 86-519-83310111
Fax: 86-519-83311577
www.globalwellife.com
Problem cause
Pressure is low
Control valve not ON
Thermocouple bad
Pilot light assembly bent
or not in correct location
Supply hose is bent or
twisted
Blockage
injector
Low gas pressure
glows
Blockage
injector
Base is not on level
surface
Low gas pressure
Blockage in burner
Dirt or film on reflector
and flame screen

TROUBLESHOOTING

Fuel tank is near empty
Turn valve to ON
Replace thermocouple
Place pilot in proper position
and retry
Straighten hose and perform
leak test on hose
in
burner
Clean
injector
Let the pilot flame stay lit for
10 minutes before setting
variable knob to "LO"
in
burner
Clean
injector
Place heater in level surface
Replace cylinder with a new
cylinder
Turn off the heater and let it
cool. Remove blockage and
clear
outside.
Clean
screen
- 18 -
solution
or
replace
or
replace
burner
inside
reflector
and
burner
burner
and
flame