Cleaning and Sanitizing –––––––––––––––––––––––––––––––––––––––––––
Cleaning and sanitizing should be performed at least every 6 months
(more often if local water conditions dictate). For initial startup, only
sanitizing is required.
WARNING!
§ Place the dispenser in Maintenance Mode prior to servicing
or cleaning the ice machine. See
Mode on page
§ For protection, rubber gloves and safety goggles (and/
or face shield) should be worn when handling Cleaner or
Sanitizer.
§ Do not mix Cleaner and Sanitizer together. It is a violation of
federal law to use these solutions in a manner inconsistent
with their labeling.
§ Do not use bleach, it will damage the dispenser.
Required Supplies
§ (3) x 7 oz. SafeCLEAN™ environmentally-friendly ice machine
cleaner packets
§ Nu-Calgon IMS-II sanitizing concentrate
§ Funnel and Bucket
Cleaning: Ice machine and Dispenser
1. Dispense all the ice out of the unit.
2. Press and hold maintenance/clean switch until
the user interface to enter Maintenance Mode.
3. Remove (unscrew) chrome ice dispense chute (Fig. 14.1).
4. Remove drip tray (Fig. 14.2).
5. Remove (2) screws located behind the drip tray (Fig. 14.3).
6. Move front panel and place on top or beside unit (Fig. 14.4).
7.
Remove plug cap from the end of drain tube (Fig. 14.5) and
lower tube to drain water into bucket.
8. After the system has been drained of water replace plug cap in drain tube.
9. Secure tube in holder.
10. Remove cap from bin lid cover (Fig. 14.6).
11. Screw bin lid cover cap onto ice discharge chute (Fig. 14.7).
12. Mix SafeCLEAN Ice Machine Cleaner, (3) x 7 oz. packets, with 11.4 L (3 gal.) of water.
13. Pour cleaning solution into bin lid access spout until solution reaches the spout neck.
14. Allow the solution to remain in unit for 15 minutes.
15. While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser.
16. Drain system by lowering drain tube into bucket.
17. Secure drain tube into holder.
18. Fill one time with potable water and drain with tube. Secure drain tube.
Sanitizing: Ice machine and Dispenser
1. Complete steps 1-11 above.
2. Mix a sanitizing solution of 9.5 L (2.5 gal.) of water and 118 ml (4 oz.) of Nu-Calgon IMS-II sanitizing
concentrate.
3. Pour sanitizing solution into bin lid access spout until solution reaches the spout neck.
4. Allow the solution to remain in unit for 5 minutes.
5. Drain system by lowering drain tube.
6. Secure drain tube into holder.
7.
Fill and drain three times with potable water.
8. Place a bucket under the dispense chute and remove cap. Note: Some sanitizing solution will remain
and drain out when cap is removed. Reposition cap on bin lid spout.
9. Reinstall front panel, ice dispense chute, and drip tray.
10. Press and hold maintenance/clean switch to exit Maintenance Mode.
Maintenance/Cleaning
11.
Fig. 14
displays in
Dispenser and Ice machine E7CI100A/E7FS100A
1
3
2
4
6
7
5
13