Service
(continued)

User Interface Display Identifi cation

––––––––––––––––––––––––––––––––––––––––––––––––––
Operation Display
PM
Condition
Normal operation
Cleaning Mode
Drip tray full
Six-month periodic
maintenance
required
Maintenance
Mode
Service - 8000 hr
bushing check
Dispenser and Ice machine E7CI100A/E7FS100A
Procedure
Press and release maintenance/
clean switch to clean the user
interface without dispensing ice
or water (see
Maintenance/
Cleaning Mode on page
Empty drip tray.
Follow Maintenance Mode
procedure (below) and also see
Cleaning and Sanitizing on
page
13.
Enter Maintenance Mode by
pressing maintenance/clean
switch until
displays.
Complete the cleaning and
sanitizing procedure shown on
page 13
and change the fi lter,
if so equipped. Exit Maintenance
Mode by pressing and holding
maintenance/clean switch until
no longer displays.
Call Follett Technical Service
Group at (877) 612-5086 or +1
(610) 252-7301. The fl ashing
wrench indicates that the 8000 hr
bushing check is required.
11).