Dell PowerConnect 8024 User Configuration Manual page 826

Hide thumbs Also See for PowerConnect 8024:
Table of Contents

Advertisement

2 Create VLAN 100. This command also enters the VLAN configuration
mode for VLAN 100.
console(config)#vlan 100
console(config-vlan100)#fip-snooping enable
console(config-vlan100)#exit
3 Enter Interface Configuration mode for ports 1, 2, 3, 16, and 17 on both
switches in the stack.
console(config)#interface range te1/0/1-
3,te1/0/16-17,te2/0/1-3,te2/0/16-17
4 Enable VLAN tagging to allow the ports to carry 802.1p priority values
through the network.
console(config-if)#switchport mode general
console(config-if)#switchport general allowed vlan
add 100 tagged
5 Exit interface configuration mode for the range of interfaces.
6 Enter interface configuration mode for the CNA-facing ports and
configure the DCBX port role as auto-downstream. This step
automatically enables PFC on the ports.
console(config)#interface te1/0/1-3,te2/0/1-3
console(config-if)#lldp dcbx port-role auto-down
console(config-if#exit
7 Enter Interface Configuration mode for the ports connect to an FCF on
both switches in the stack to configure the DCBX port role as auto-
upstream.
console(config)#interface te1/0/16-17,te2/0/16-17
console(config-if)#lldp dcbx port-role auto-up
8 Set the FIP snooping port mode as
connected to a Fibre Channel forwarder.
console(config-if)#fip-snooping port-mode fcf
console(config-if)#exit
9 Optionally, use the FIP snooping show commands to verify the
configuration, view FIP snooping sessions, and view information about the
ports that are connected to end nodes or FCFs.
826
Configuring Data Center Features
fcf to indicate that these ports are