Message and Recovery Procedures
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-NEIGHBOR_SSLS: Switch [dec] [dec] neighbor
switch experienced a system star load shed event
Explanation
[dec] and second [dec] are the stack member numbers on each side of the neighbor. One example of
an SSLS event is a situation in which a switch is physically removed from the power stack by a cable
removal and that switch is a sourcing system in a star topology.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-NEIGHBOR_UVLS: Switch [dec] [dec] neighbor
switch experienced an under voltage load shed event
Explanation
second [dec] are the stack member numbers on each side of the neighbor.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-BISP_POE_OVER_I: Switch [dec] experienced a PoE
over-current BISP event
Explanation
(BISP) event that was caused by an overcurrent condition. [dec] is the stack member number.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
OL-9772-05
A neighbor switch shut down because of a system star load shed (SSLS) event. The first
Copy the message exactly as it appears on the console or in the system log.
A neighbor switch shut down because of a low-voltage condition. The first [dec] and
Copy the message exactly as it appears on the console or in the system log.
Ports stopped providing Power over Ethernet (PoE) because of a built-in self protection
Copy the message exactly as it appears on the console or in the system log.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
PLATFORM_STACKPOWER Messages
1-7.
1-7.
1-7.
1-7.
"Error
"Error
"Error