FRNTEND_CTRLR Messages

FRNTEND_CTRLR Messages
These messages apply only to the Catalyst 3750-X and 3750-E switches.
Note
Error Message FRNTEND_CTRLR-1-MGR_TXQ_FULL: The front end controller Tx queue
reached watermark level
Error Message FRNTEND_CTRLR-2-SUB_INACTIVE: The front end controller [dec] is
inactive.

GBIC_SECURITY Messages

The Catalyst 3750-X, 3750-E, 3560-X, and 3560-E switches support SFP modules and do not support
Note
GBIC modules. Although the error message text refers to GBIC interfaces and modules, the messages
from the switches actually refer to the SFP and 10-Gigabit Ethernet module interfaces and modules.
Error Message GBIC_SECURITY-4-EEPROM_CRC_ERR: EEPROM checksum error for GBIC in
[chars].
Error Message GBIC_SECURITY-4-EEPROM_READ_ERR: Error in reading GBIC serial ID in
[chars].
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
2-36
Explanation
There are too many messages in the queue between the front-end controller and the
switch software.
Reset the switch. If the problem is not resolved, contact your Cisco technical
Recommended Action
support representative because there might be a problem with the switch.
Explanation
The front-end controller that controls the LEDs, the PoE features, and the fan-control
features is now inactive on the port controlled by the front-end controller. This does not affect the
traffic on the port. [dec] is the controller number.
Recommended Action
Reset the switch. If the problem is not resolved, contact your Cisco technical
support representative because there might be a problem with the switch.
The GBIC in the specified port has invalid EEPROM data. [chars] is the port in which
Explanation
the GBIC is inserted.
Remove the GBIC from the port.
Recommended Action
An error occurred while the switch was reading the GBIC type from the EEPROM.
Explanation
[chars] is the port in which the GBIC is inserted.
Remove the GBIC from the port.
Recommended Action