Chapter 2
Message and Recovery Procedures
Error Message PLATFORM_ENV-1-FRU_PS_SIGNAL_OK:[chars] signal on power supply is
restored.
Explanation
(12V or PoE).
Recommended Action
Error Message PLATFORM_ENV-1-PS_NONPOE: Internal Power supply not adequate for
inline power.
Explanation
(PoE) ports.
Recommended Action
Error Message PLATFORM_ENV-1-RPS_ACCESS: [chars].
Explanation
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_ENV-1-RPS_FAN_FAILED: [chars].
Explanation
Recommended Action
the fan.
Error Message PLATFORM_ENV-1-RPS_OVER_CURRENT: [chars].
Explanation
Recommended Action
them.
Error Message PLATFORM_ENV-1-RPS_PS_FAN_FAILED: RPS power supply fan failure
detected [chars].
Explanation
B).
Recommended Action
the power supply.
OL-9772-05
The specified signal of the power supply has been restored. [chars] is the signal value
No action is required.
The internal power supply does not provide enough power for the Power over Ethernet
Substitute a power supply that can provide enough power for the PoE ports.
An RPS 2300 communication error is detected. [chars] is the error message.
Copy the message exactly as it appears on the console or in the system log.
An RPS 2300 fan failure is detected. [chars] is the error message.
Disconnect any switches connected to the RPS 2300, and immediately replace
An RPS 2300 over current condition is detected. [chars] is the error message.
Disconnect the switches from the RPS 2300 that is not providing power to
An RPS 2300 power supply fan failure is detected. [chars] is the power supply ID (A or
Disconnect any switches connected to the RPS 2300, and immediately replace
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
1-7.
PLATFORM_ENV Messages
"Error
2-57