Dwl Messages; Ec Messages - Cisco Catalyst 3750-X Message Manual

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

Chapter 2
Message and Recovery Procedures
Error Message DTP-5-TRUNKPORTON: Port [chars] has become [chars] trunk.

DWL Messages

Error Message DWL-3-LOOP_BACK_DETECTED: Loop-back detected on [chars].

EC Messages

Error Message EC-4-NOMEM: Not enough memory available for [chars].
Error Message EC-5-BUNDLE: Interface [chars] joined port-channel [chars].
Error Message EC-5-CANNOT_ALLOCATE_AGGREGATOR: Aggregator limit reached, cannot
allocate aggregator for group [dec]
OL-9772-05
The interface has changed from an access port to a trunk port. The first [chars] is the
Explanation
interface, and the second [chars] is the encapsulation type.
Recommended Action
This message is provided only for information.
Explanation
There is a loopback on the specified port that might be caused by a Token-Ring Type-1
cable connected to the port or a misconfiguration in the network. [chars] is the port.
Correct the problem that is causing the loopback condition. Then enter the
Recommended Action
shutdown and the no shutdown interface configuration commands.
Explanation
Either the LACP or the PAgP EtherChannel could not get the memory it needed to
initialize the required data structures. [chars] is the data structure name.
Copy the message exactly as it appears on the console or in the system log.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Explanation
The listed interface joined the specified EtherChannel. The first [chars] is the physical
interface, and the second [chars] is the EtherChannel interface.
No action is required.
Recommended Action
A new aggregator cannot be allocated in the group. [dec] is the affected group.
Explanation
Change the port attributes of the ports in the group so that they match and join
Recommended Action
the same aggregator.
1-7.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
DWL Messages
"Error
2-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-xCatalyst 3560-eCatalyst 3750-e

Table of Contents